What size AC for Wilson, NC? 3.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Wilson needs
3.5 tons central AC or heat pump, about 36,900 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 651 square feet in this climate. For a single room, size by the room: 18.4 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Rocky Mount Wilson Airport (8.5 mi away). Jul is the hottest month, averaging a high of 90.5°F and a low of 69°F, with about 54 days a year at 90°F or more. That gives a design temperature of 96°F against 75°F inside.
What it costs to run
About 2,478 kWh a year at SEER2 14.3, or roughly $370 at North Carolina's average residential rate of 14.94¢ per kWh. Cooling runs 6 months of the year here.
What drives the load in Wilson
Of the 36,900 BTU/hr, 15,120 comes through walls, roof and windows on a 96°F afternoon (41%), 13,000 is sun on the house (35%), 2,120 is four people and their appliances, and 6,700 is moisture the coil has to wring out of Wilson's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,240 BTU/hr before the moisture allowance.
Other house sizes in Wilson
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 19,700 | 1.5 tons | 2 tons |
| 1,500 sq ft | 28,300 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 45,500 | 4 tons | 5 tons |
| 3,000 sq ft | 54,000 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,000 BTU/hr.
Month by month in Wilson
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 51.8°F | 0 | 0 |
| Feb | 55.3°F | 2 | 3 |
| Mar | 63.2°F | 8 | 12 |
| Apr | 72.5°F | 45 | 66 |
| May | 79.9°F | 149 | 220 |
| Jun | 86.9°F | 327 | 483 |
| Jul | 90.5°F | 457 | 674 |
| Aug | 88.3°F | 403 | 594 |
| Sep | 82.5°F | 229 | 337 |
| Oct | 73.1°F | 54 | 80 |
| Nov | 62.8°F | 5 | 8 |
| Dec | 54.7°F | 2 | 2 |
Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 961 hours a year at full output.
Wilson against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Rocky Mount, NC | 18 mi | 96°F | 3.5 tons |
| Zebulon, NC | 23 mi | 96°F | 3.5 tons |
| Wendell, NC | 24 mi | 97°F | 3.5 tons |
| Tarboro, NC | 24 mi | 95°F | 3 tons |
| Goldsboro, NC | 25 mi | 97°F | 3.5 tons |
| Smithfield, NC | 28 mi | 97°F | 3.5 tons |
Of 91 North Carolina cities here, Wilson has the 34th highest cooling load. The range runs from Boone at 21,700 BTU/hr to Lumberton at 40,200.
Where Wilson's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Rocky Mount Wilson Airport, 8.5 miles from the center of Wilson at 150 ft above sea level. That is close enough that the station's summers are Wilson's summers.
2 other cities use the same station and get the same climate inputs. The closest to Wilson: Rocky Mount (18 mi away, 9.5 mi from the station), Zebulon (23 mi away, 23.5 mi from the station). Wilson sits closer to the station than any of them, so its numbers are the best measured of the group.
The sun over Wilson in late July
At 35.73°N, the noon sun on 21 July stands 74.7° above the horizon over Wilson and the day runs 14 h 04 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
48,579 people live in Wilson, the 24th largest of the 91 North Carolina cities sized on this site. Coordinates used: 35.7315, -77.9308.
Wilson AC sizing questions
What size AC does a 2,000 sq ft house in Wilson, NC need?
About 3.5 tons, for a cooling load of 36,900 BTU/hr on a 96°F design day. That is one ton per 651 square feet in Wilson's climate.
Is 20 BTU per square foot right for Wilson?
The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Rocky Mount Wilson Airport. For a single room here, plan on 18.4 BTU/hr per square foot.
What does central AC cost to run in Wilson?
About $370 a year: 2,478 kWh at SEER2 14.3 and 14.94¢ per kWh, over 6 cooling months.