What size AC for Wendell, NC? 3.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Wendell needs
3.5 tons central AC or heat pump, about 37,800 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 635 square feet in this climate. For a single room, size by the room: 18.9 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Raleigh Airport (25.1 mi away). Jul is the hottest month, averaging a high of 90.8°F and a low of 70.2°F, with about 52 days a year at 90°F or more. That gives a design temperature of 97°F against 75°F inside.
What it costs to run
About 2,660 kWh a year at SEER2 14.3, or roughly $397 at North Carolina's average residential rate of 14.94¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Wendell
Of the 37,800 BTU/hr, 15,840 comes through walls, roof and windows on a 97°F afternoon (42%), 13,000 is sun on the house (34%), 2,120 is four people and their appliances, and 6,800 is moisture the coil has to wring out of Wendell's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,960 BTU/hr before the moisture allowance.
Other house sizes in Wendell
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 20,200 | 2 tons | 2 tons |
| 1,500 sq ft | 29,000 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 46,600 | 4 tons | 5 tons |
| 3,000 sq ft | 55,400 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,300 BTU/hr.
Month by month in Wendell
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 51.9°F | 1 | 1 |
| Feb | 55.8°F | 2 | 3 |
| Mar | 63.3°F | 12 | 17 |
| Apr | 72.7°F | 54 | 80 |
| May | 80°F | 166 | 245 |
| Jun | 87.4°F | 354 | 522 |
| Jul | 90.8°F | 480 | 708 |
| Aug | 88.7°F | 428 | 631 |
| Sep | 82.5°F | 243 | 358 |
| Oct | 73°F | 56 | 83 |
| Nov | 63°F | 7 | 10 |
| Dec | 54.7°F | 3 | 4 |
Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 1,007 hours a year at full output.
Wendell against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Zebulon, NC | 3 mi | 96°F | 3.5 tons |
| Knightdale, NC | 8 mi | 97°F | 3.5 tons |
| Rolesville, NC | 11 mi | 97°F | 3.5 tons |
| Clayton, NC | 11 mi | 94°F | 3 tons |
| Wake Forest, NC | 15 mi | 97°F | 3.5 tons |
| Garner, NC | 16 mi | 97°F | 3.5 tons |
Of 91 North Carolina cities here, Wendell has the 24th highest cooling load. The range runs from Boone at 21,700 BTU/hr to Lumberton at 40,200.
Where Wendell's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Raleigh Airport, 25.1 miles from the center of Wendell at 395 ft above sea level. That is a long way for a weather station, so treat the design day as approximate: a city on the coast side or the high side of the station can run several degrees different.
11 other cities use the same station and get the same climate inputs. The closest to Wendell: Knightdale (8 mi away, 17.4 mi from the station), Rolesville (11 mi away, 17.9 mi from the station), Wake Forest (15 mi away, 15.9 mi from the station), Garner (16 mi away, 16.9 mi from the station), Raleigh (16 mi away, 8.9 mi from the station). Wendell is farther from the station than 11 of them.
The sun over Wendell in late July
At 35.79°N, the noon sun on 21 July stands 74.6° above the horizon over Wendell and the day runs 14 h 04 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
16,845 people live in Wendell, the 66th largest of the 91 North Carolina cities sized on this site. Coordinates used: 35.7936, -78.3511.
Wendell AC sizing questions
What size AC does a 2,000 sq ft house in Wendell, NC need?
About 3.5 tons, for a cooling load of 37,800 BTU/hr on a 97°F design day. That is one ton per 635 square feet in Wendell's climate.
Is 20 BTU per square foot right for Wendell?
The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Raleigh Airport. For a single room here, plan on 18.9 BTU/hr per square foot.
What does central AC cost to run in Wendell?
About $397 a year: 2,660 kWh at SEER2 14.3 and 14.94¢ per kWh, over 7 cooling months.