What size AC for Tarboro, NC? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Tarboro needs
3 tons central AC or heat pump, about 36,000 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 17% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 666 square feet in this climate. For a single room, size by the room: 18 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Tarboro 1 S (1.8 mi away). Jul is the hottest month, averaging a high of 89.3°F and a low of 70.3°F, with about 43 days a year at 90°F or more. That gives a design temperature of 95°F against 75°F inside.
What it costs to run
About 2,488 kWh a year at SEER2 14.3, or roughly $372 at North Carolina's average residential rate of 14.94¢ per kWh. Cooling runs 6 months of the year here.
What drives the load in Tarboro
Of the 36,000 BTU/hr, 14,400 comes through walls, roof and windows on a 95°F afternoon (40%), 13,000 is sun on the house (36%), 2,120 is four people and their appliances, and 6,500 is moisture the coil has to wring out of Tarboro's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 29,520 BTU/hr before the moisture allowance.
Other house sizes in Tarboro
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 19,300 | 1.5 tons | 2 tons |
| 1,500 sq ft | 27,700 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 44,400 | 4 tons | 5 tons |
| 3,000 sq ft | 52,700 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,700 BTU/hr; a 350 sq ft living room needs about 6,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,800 BTU/hr.
Month by month in Tarboro
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 51.4°F | 1 | 1 |
| Feb | 54.7°F | 1 | 1 |
| Mar | 61.9°F | 6 | 9 |
| Apr | 71.8°F | 39 | 58 |
| May | 78.8°F | 147 | 217 |
| Jun | 85.9°F | 331 | 488 |
| Jul | 89.3°F | 459 | 676 |
| Aug | 87.3°F | 406 | 599 |
| Sep | 82.1°F | 236 | 348 |
| Oct | 73°F | 54 | 79 |
| Nov | 63.1°F | 6 | 9 |
| Dec | 55.2°F | 2 | 3 |
Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 988 hours a year at full output.
Tarboro against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Rocky Mount, NC | 15 mi | 96°F | 3.5 tons |
| Greenville, NC | 24 mi | 96°F | 3.5 tons |
| Wilson, NC | 24 mi | 96°F | 3.5 tons |
| Winterville, NC | 27 mi | 96°F | 3.5 tons |
| Roanoke Rapids, NC | 38 mi | 95°F | 3 tons |
| Zebulon, NC | 43 mi | 96°F | 3.5 tons |
Of 91 North Carolina cities here, Tarboro has the 62nd highest cooling load. The range runs from Boone at 21,700 BTU/hr to Lumberton at 40,200.
Where Tarboro's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Tarboro 1 S, 1.8 miles from the center of Tarboro at 35 ft above sea level. That is close enough that the station's summers are Tarboro's summers.
No other city in this set uses Tarboro 1 S, so this sizing is Tarboro's alone.
The sun over Tarboro in late July
At 35.91°N, the noon sun on 21 July stands 74.5° above the horizon over Tarboro and the day runs 14 h 05 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
10,954 people live in Tarboro, the 87th largest of the 91 North Carolina cities sized on this site. Coordinates used: 35.9052, -77.5572.
Tarboro AC sizing questions
What size AC does a 2,000 sq ft house in Tarboro, NC need?
About 3 tons, for a cooling load of 36,000 BTU/hr on a 95°F design day. That is one ton per 666 square feet in Tarboro's climate.
Is 20 BTU per square foot right for Tarboro?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Tarboro 1 S. For a single room here, plan on 18 BTU/hr per square foot.
What does central AC cost to run in Tarboro?
About $372 a year: 2,488 kWh at SEER2 14.3 and 14.94¢ per kWh, over 6 cooling months.