What size AC for Snyder, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Snyder needs
4 tons central AC or heat pump, about 43,000 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.6 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 558 square feet in this climate. For a single room, size by the room: 21.5 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Snyder (0.3 mi away). Jul is the hottest month, averaging a high of 95.6°F and a low of 70.3°F, with about 101 days a year at 90°F or more. That gives a design temperature of 103°F against 75°F inside.
What it costs to run
About 3,343 kWh a year at SEER2 14.3, or roughly $536 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Snyder
Of the 43,000 BTU/hr, 20,160 comes through walls, roof and windows on a 103°F afternoon (47%), 13,000 is sun on the house (30%), 2,120 is four people and their appliances, and 7,800 is moisture the coil has to wring out of Snyder's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 35,280 BTU/hr before the moisture allowance.
Other house sizes in Snyder
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 22,800 | 2 tons | 2 tons |
| 1,500 sq ft | 32,900 | 3 tons | 2.5 tons |
| 2,500 sq ft | 53,200 | 5 tons | 5 tons |
| 3,000 sq ft | 63,300 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,900 BTU/hr.
Month by month in Snyder
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 57°F | 0 | 0 |
| Feb | 61.5°F | 2 | 2 |
| Mar | 69.7°F | 17 | 24 |
| Apr | 78.3°F | 76 | 113 |
| May | 85.7°F | 250 | 369 |
| Jun | 92.4°F | 443 | 653 |
| Jul | 95.6°F | 556 | 820 |
| Aug | 94.4°F | 526 | 775 |
| Sep | 87°F | 297 | 438 |
| Oct | 78°F | 94 | 138 |
| Nov | 66°F | 7 | 10 |
| Dec | 57.7°F | 0 | 0 |
Jul alone uses 25% of the year's cooling energy. The unit runs the equivalent of 1,111 hours a year at full output.
Snyder against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Sweetwater, TX | 34 mi | 102°F | 4 tons |
| Big Spring, TX | 47 mi | 104°F | 4 tons |
| Abilene, TX | 71 mi | 104°F | 4 tons |
| Lubbock, TX | 81 mi | 100°F | 3.5 tons |
| Midland, TX | 85 mi | 104°F | 4 tons |
| San Angelo, TX | 92 mi | 105°F | 4 tons |
Of 252 Texas cities here, Snyder has the 221st highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where Snyder's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Snyder, 0.3 miles from the center of Snyder at 2,319 ft above sea level. That is close enough that the station's summers are Snyder's summers.
No other city in this set uses Snyder, so this sizing is Snyder's alone.
The sun over Snyder in late July
At 32.71°N, the noon sun on 21 July stands 77.7° above the horizon over Snyder and the day runs 13 h 51 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
11,151 people live in Snyder, the 229th largest of the 252 Texas cities sized on this site. Coordinates used: 32.7136, -100.9119.
Snyder AC sizing questions
What size AC does a 2,000 sq ft house in Snyder, TX need?
About 4 tons, for a cooling load of 43,000 BTU/hr on a 103°F design day. That is one ton per 558 square feet in Snyder's climate.
Is 20 BTU per square foot right for Snyder?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Snyder. For a single room here, plan on 21.5 BTU/hr per square foot.
What does central AC cost to run in Snyder?
About $536 a year: 3,343 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.