ACSizeCheck

What size AC for Lubbock, TX? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Lubbock needs

3.5 tons central AC or heat pump, about 40,400 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.4 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 594 square feet in this climate. For a single room, size by the room: 20.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Lubbock (7.7 mi away). Jul is the hottest month, averaging a high of 93.4°F and a low of 69°F, with about 92 days a year at 90°F or more. That gives a design temperature of 100°F against 75°F inside.

What it costs to run

About 2,875 kWh a year at SEER2 14.3, or roughly $461 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Lubbock

Of the 40,400 BTU/hr, 18,000 comes through walls, roof and windows on a 100°F afternoon (45%), 13,000 is sun on the house (32%), 2,120 is four people and their appliances, and 7,300 is moisture the coil has to wring out of Lubbock's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,120 BTU/hr before the moisture allowance.

Other house sizes in Lubbock

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft21,5002 tons2 tons
1,500 sq ft31,0002.5 tons2.5 tons
2,500 sq ft49,9004 tons5 tons
3,000 sq ft59,3005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,000 BTU/hr; a 350 sq ft living room needs about 7,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,100 BTU/hr.

Month by month in Lubbock

MonthAvg highCooling degree daysAC kWh
Jan55°F00
Feb59.7°F11
Mar67.8°F1015
Apr76°F5379
May84.2°F210310
Jun91.6°F409603
Jul93.4°F502741
Aug92.2°F460679
Sep84.9°F240354
Oct75.5°F6189
Nov63.8°F45
Dec55.1°F00

Jul alone uses 26% of the year's cooling energy. The unit runs the equivalent of 1,018 hours a year at full output.

Lubbock against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Levelland, TX27 mi99°F3.5 tons
Plainview, TX44 mi99°F3.5 tons
Snyder, TX81 mi103°F4 tons
Hereford, TX92 mi99°F3.5 tons
Hobbs, NM93 mi102°F4 tons
Andrews, TX94 mi103°F4 tons

Of 252 Texas cities here, Lubbock has the 242nd highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Lubbock's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Lubbock, 7.7 miles from the center of Lubbock at 3,378 ft above sea level. That is close enough that the station's summers are Lubbock's summers.

No other city in this set uses Lubbock, so this sizing is Lubbock's alone.

The sun over Lubbock in late July

At 33.56°N, the noon sun on 21 July stands 76.8° above the horizon over Lubbock and the day runs 13 h 54 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

272,086 people live in Lubbock, the 10th largest of the 252 Texas cities sized on this site. Coordinates used: 33.5619, -101.8889.

Lubbock AC sizing questions

What size AC does a 2,000 sq ft house in Lubbock, TX need?

About 3.5 tons, for a cooling load of 40,400 BTU/hr on a 100°F design day. That is one ton per 594 square feet in Lubbock's climate.

Is 20 BTU per square foot right for Lubbock?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Lubbock. For a single room here, plan on 20.2 BTU/hr per square foot.

What does central AC cost to run in Lubbock?

About $461 a year: 2,875 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.