ACSizeCheck

What size AC for Sweetwater, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Sweetwater needs

4 tons central AC or heat pump, about 42,200 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.5 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 569 square feet in this climate. For a single room, size by the room: 21.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Roscoe (7 mi away). Jul is the hottest month, averaging a high of 94.6°F and a low of 71.3°F, with about 97 days a year at 90°F or more. That gives a design temperature of 102°F against 75°F inside.

What it costs to run

About 3,377 kWh a year at SEER2 14.3, or roughly $541 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Sweetwater

Of the 42,200 BTU/hr, 19,440 comes through walls, roof and windows on a 102°F afternoon (46%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 7,600 is moisture the coil has to wring out of Sweetwater's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 34,560 BTU/hr before the moisture allowance.

Other house sizes in Sweetwater

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,4002 tons2 tons
1,500 sq ft32,3003 tons2.5 tons
2,500 sq ft52,1004 tons5 tons
3,000 sq ft62,0005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,700 BTU/hr.

Month by month in Sweetwater

MonthAvg highCooling degree daysAC kWh
Jan55.5°F00
Feb60.3°F34
Mar68.7°F1929
Apr77.8°F86127
May84.8°F256377
Jun91.1°F437644
Jul94.6°F557820
Aug93.5°F527777
Sep85.7°F297437
Oct76.5°F100148
Nov64.8°F913
Dec56.8°F01

Jul alone uses 24% of the year's cooling energy. The unit runs the equivalent of 1,145 hours a year at full output.

Sweetwater against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Snyder, TX34 mi103°F4 tons
Abilene, TX39 mi104°F4 tons
Big Spring, TX65 mi104°F4 tons
San Angelo, TX71 mi105°F4 tons
Brownwood, TX99 mi105°F4 tons
Midland, TX104 mi104°F4 tons

Of 252 Texas cities here, Sweetwater has the 229th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Sweetwater's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Roscoe, 7 miles from the center of Sweetwater at 2,380 ft above sea level. That is close enough that the station's summers are Sweetwater's summers.

No other city in this set uses Roscoe, so this sizing is Sweetwater's alone.

The sun over Sweetwater in late July

At 32.47°N, the noon sun on 21 July stands 77.9° above the horizon over Sweetwater and the day runs 13 h 50 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

10,196 people live in Sweetwater, the 247th largest of the 252 Texas cities sized on this site. Coordinates used: 32.4694, -100.4087.

Sweetwater AC sizing questions

What size AC does a 2,000 sq ft house in Sweetwater, TX need?

About 4 tons, for a cooling load of 42,200 BTU/hr on a 102°F design day. That is one ton per 569 square feet in Sweetwater's climate.

Is 20 BTU per square foot right for Sweetwater?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Roscoe. For a single room here, plan on 21.1 BTU/hr per square foot.

What does central AC cost to run in Sweetwater?

About $541 a year: 3,377 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.