What size AC for San Angelo, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in San Angelo needs
4 tons central AC or heat pump, about 47,700 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 503 square feet in this climate. For a single room, size by the room: 23.9 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at San Angelo (5.4 mi away). Jul is the hottest month, averaging a high of 97.4°F and a low of 72.3°F, with about 119 days a year at 90°F or more. That gives a design temperature of 105°F against 75°F inside.
What it costs to run
About 4,376 kWh a year at SEER2 14.3, or roughly $701 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in San Angelo
Of the 47,700 BTU/hr, 21,600 comes through walls, roof and windows on a 105°F afternoon (45%), 13,000 is sun on the house (27%), 2,120 is four people and their appliances, and 11,000 is moisture the coil has to wring out of San Angelo's summer air (23%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,720 BTU/hr before the moisture allowance.
Other house sizes in San Angelo
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 25,200 | 2 tons | 2 tons |
| 1,500 sq ft | 36,500 | 3 tons | 2.5 tons |
| 2,500 sq ft | 59,000 | 5 tons | 5 tons |
| 3,000 sq ft | 70,200 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,600 BTU/hr; a 350 sq ft living room needs about 8,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,300 BTU/hr.
Month by month in San Angelo
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 61.1°F | 1 | 2 |
| Feb | 65.4°F | 8 | 12 |
| Mar | 73.1°F | 47 | 74 |
| Apr | 81.7°F | 138 | 216 |
| May | 88.7°F | 336 | 528 |
| Jun | 94.4°F | 516 | 811 |
| Jul | 97.4°F | 615 | 967 |
| Aug | 96.7°F | 594 | 932 |
| Sep | 89.4°F | 366 | 574 |
| Oct | 80.5°F | 142 | 224 |
| Nov | 69.2°F | 21 | 33 |
| Dec | 62°F | 2 | 3 |
Jul alone uses 22% of the year's cooling energy. The unit runs the equivalent of 1,311 hours a year at full output.
San Angelo against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Sweetwater, TX | 71 mi | 102°F | 4 tons |
| Abilene, TX | 82 mi | 104°F | 4 tons |
| Big Spring, TX | 82 mi | 104°F | 4 tons |
| Brownwood, TX | 89 mi | 105°F | 4 tons |
| Snyder, TX | 92 mi | 103°F | 4 tons |
| Midland, TX | 106 mi | 104°F | 4 tons |
Of 252 Texas cities here, San Angelo has the 39th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where San Angelo's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is San Angelo, 5.4 miles from the center of San Angelo at 2,004 ft above sea level. That is close enough that the station's summers are San Angelo's summers.
No other city in this set uses San Angelo, so this sizing is San Angelo's alone.
The sun over San Angelo in late July
At 31.44°N, the noon sun on 21 July stands 79.0° above the horizon over San Angelo and the day runs 13 h 45 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
100,159 people live in San Angelo, the 44th largest of the 252 Texas cities sized on this site. Coordinates used: 31.4411, -100.4505.
San Angelo AC sizing questions
What size AC does a 2,000 sq ft house in San Angelo, TX need?
About 4 tons, for a cooling load of 47,700 BTU/hr on a 105°F design day. That is one ton per 503 square feet in San Angelo's climate.
Is 20 BTU per square foot right for San Angelo?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at San Angelo. For a single room here, plan on 23.9 BTU/hr per square foot.
What does central AC cost to run in San Angelo?
About $701 a year: 4,376 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.