What size AC for Levelland, TX? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Levelland needs

3.5 tons central AC or heat pump, about 37,300 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 644 square feet in this climate. For a single room, size by the room: 18.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Levelland (2.3 mi away). Jul is the hottest month, averaging a high of 92.4°F and a low of 65.6°F, with about 87 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.

What it costs to run

About 2,221 kWh a year at SEER2 14.3, or roughly $356 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Levelland

Of the 37,300 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (46%), 13,000 is sun on the house (35%), 2,120 is four people and their appliances, and 4,900 is moisture the coil has to wring out of Levelland's summer air (13%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.

Other house sizes in Levelland

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft19,8001.5 tons2 tons
1,500 sq ft28,6002.5 tons2.5 tons
2,500 sq ft46,0004 tons5 tons
3,000 sq ft54,7005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,200 BTU/hr.

Month by month in Levelland

MonthAvg highCooling degree daysAC kWh
Jan53.7°F00
Feb58.5°F00
Mar66.5°F34
Apr75.2°F2636
May83.7°F166230
Jun91.3°F363504
Jul92.4°F434604
Aug90.5°F382531
Sep83.5°F185257
Oct74.7°F3852
Nov62.7°F12
Dec54.4°F00

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 852 hours a year at full output.

Levelland against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Lubbock, TX27 mi100°F3.5 tons
Plainview, TX56 mi99°F3.5 tons
Portales, NM70 mi100°F3.5 tons
Lovington, NM72 mi102°F3.5 tons
Hobbs, NM75 mi102°F4 tons
Clovis, NM76 mi99°F3.5 tons

Of 252 Texas cities here, Levelland has the lowest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Levelland's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Levelland, 2.3 miles from the center of Levelland at 3,514 ft above sea level. That is close enough that the station's summers are Levelland's summers.

No other city in this set uses Levelland, so this sizing is Levelland's alone.

The sun over Levelland in late July

At 33.58°N, the noon sun on 21 July stands 76.8° above the horizon over Levelland and the day runs 13 h 54 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

12,494 people live in Levelland, the 216th largest of the 252 Texas cities sized on this site. Coordinates used: 33.5815, -102.3641.

Levelland AC sizing questions

What size AC does a 2,000 sq ft house in Levelland, TX need?

About 3.5 tons, for a cooling load of 37,300 BTU/hr on a 99°F design day. That is one ton per 644 square feet in Levelland's climate.

Is 20 BTU per square foot right for Levelland?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Levelland. For a single room here, plan on 18.6 BTU/hr per square foot.

What does central AC cost to run in Levelland?

About $356 a year: 2,221 kWh at SEER2 14.3 and 16.03¢ per kWh, over 5 cooling months.