ACSizeCheck

What size AC for Hopkinsville, KY? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Hopkinsville needs

3 tons central AC or heat pump, about 33,100 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 27% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 725 square feet in this climate. For a single room, size by the room: 16.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Clarksville Outlaw Airport (15.7 mi away). Aug is the hottest month, averaging a high of 88.7°F and a low of 66.2°F, with about 43 days a year at 90°F or more. That gives a design temperature of 94°F against 75°F inside.

What it costs to run

About 2,098 kWh a year at SEER2 14.3, or roughly $298 at Kentucky's average residential rate of 14.2¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Hopkinsville

Of the 33,100 BTU/hr, 13,680 comes through walls, roof and windows on a 94°F afternoon (41%), 13,000 is sun on the house (39%), 2,120 is four people and their appliances, and 4,300 is moisture the coil has to wring out of Hopkinsville's summer air (13%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 28,800 BTU/hr before the moisture allowance.

Other house sizes in Hopkinsville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft17,8001.5 tons2 tons
1,500 sq ft25,4002 tons2.5 tons
2,500 sq ft40,8003.5 tons5 tons
3,000 sq ft48,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,500 BTU/hr; a 350 sq ft living room needs about 5,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,000 BTU/hr.

Month by month in Hopkinsville

MonthAvg highCooling degree daysAC kWh
Jan46.2°F01
Feb50.8°F12
Mar60°F68
Apr70°F3447
May77.8°F134187
Jun85.6°F302419
Jul88.5°F409569
Aug88.7°F386537
Sep82.4°F194270
Oct71.5°F4055
Nov59°F34
Dec48.9°F00

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 906 hours a year at full output.

Hopkinsville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Clarksville, TN20 mi94°F3 tons
Madisonville, KY35 mi95°F3 tons
Springfield, TN41 mi94°F3 tons
Murray, KY50 mi95°F3 tons
Franklin, KY51 mi95°F3 tons
White House, TN52 mi94°F3 tons

Of 42 Kentucky cities here, Hopkinsville has the 16th highest cooling load. The range runs from Versailles at 29,000 BTU/hr to Paducah at 36,900.

Where Hopkinsville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Clarksville Outlaw Airport, across the line in Tennessee, 15.7 miles from the center of Hopkinsville at 550 ft above sea level. That is close enough that the station's summers are Hopkinsville's summers.

1 other city uses the same station and get the same climate inputs. The closest to Hopkinsville: Clarksville (20 mi away, 5.1 mi from the station). Hopkinsville is farther from the station than 1 of them.

The sun over Hopkinsville in late July

At 36.84°N, the noon sun on 21 July stands 73.6° above the horizon over Hopkinsville and the day runs 14 h 09 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

30,800 people live in Hopkinsville, the 11th largest of the 42 Kentucky cities sized on this site. Coordinates used: 36.8393, -87.4735.

Hopkinsville AC sizing questions

What size AC does a 2,000 sq ft house in Hopkinsville, KY need?

About 3 tons, for a cooling load of 33,100 BTU/hr on a 94°F design day. That is one ton per 725 square feet in Hopkinsville's climate.

Is 20 BTU per square foot right for Hopkinsville?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Clarksville Outlaw Airport. For a single room here, plan on 16.6 BTU/hr per square foot.

What does central AC cost to run in Hopkinsville?

About $298 a year: 2,098 kWh at SEER2 14.3 and 14.2¢ per kWh, over 5 cooling months.