What size AC for Madisonville, KY? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Madisonville needs
3 tons central AC or heat pump, about 36,000 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 17% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 666 square feet in this climate. For a single room, size by the room: 18 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Madisonville (1.2 mi away). Jul is the hottest month, averaging a high of 89.3°F and a low of 69.9°F, with about 53 days a year at 90°F or more. That gives a design temperature of 95°F against 75°F inside.
What it costs to run
About 2,600 kWh a year at SEER2 14.3, or roughly $369 at Kentucky's average residential rate of 14.2¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Madisonville
Of the 36,000 BTU/hr, 14,400 comes through walls, roof and windows on a 95°F afternoon (40%), 13,000 is sun on the house (36%), 2,120 is four people and their appliances, and 6,500 is moisture the coil has to wring out of Madisonville's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 29,520 BTU/hr before the moisture allowance.
Other house sizes in Madisonville
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 19,300 | 1.5 tons | 2 tons |
| 1,500 sq ft | 27,700 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 44,400 | 4 tons | 5 tons |
| 3,000 sq ft | 52,700 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,700 BTU/hr; a 350 sq ft living room needs about 6,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,800 BTU/hr.
Month by month in Madisonville
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 44.8°F | 0 | 0 |
| Feb | 49.9°F | 1 | 1 |
| Mar | 60°F | 10 | 15 |
| Apr | 71.5°F | 56 | 82 |
| May | 79.1°F | 174 | 256 |
| Jun | 86.3°F | 347 | 511 |
| Jul | 89.3°F | 453 | 667 |
| Aug | 88.7°F | 419 | 617 |
| Sep | 83.1°F | 238 | 351 |
| Oct | 71.9°F | 60 | 89 |
| Nov | 58.4°F | 6 | 9 |
| Dec | 48°F | 0 | 1 |
Jul alone uses 26% of the year's cooling energy. The unit runs the equivalent of 1,032 hours a year at full output.
Madisonville against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Hopkinsville, KY | 35 mi | 94°F | 3 tons |
| Henderson, KY | 35 mi | 94°F | 3 tons |
| Owensboro, KY | 36 mi | 94°F | 3 tons |
| Evansville, IN | 45 mi | 94°F | 3 tons |
| Clarksville, TN | 54 mi | 94°F | 3 tons |
| Bowling Green, KY | 64 mi | 95°F | 3 tons |
Of 42 Kentucky cities here, Madisonville has the 3rd highest cooling load. The range runs from Versailles at 29,000 BTU/hr to Paducah at 36,900.
Where Madisonville's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Madisonville, 1.2 miles from the center of Madisonville at 425 ft above sea level. That is close enough that the station's summers are Madisonville's summers.
No other city in this set uses Madisonville, so this sizing is Madisonville's alone.
The sun over Madisonville in late July
At 37.34°N, the noon sun on 21 July stands 73.1° above the horizon over Madisonville and the day runs 14 h 12 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
19,502 people live in Madisonville, the 20th largest of the 42 Kentucky cities sized on this site. Coordinates used: 37.3393, -87.5037.
Madisonville AC sizing questions
What size AC does a 2,000 sq ft house in Madisonville, KY need?
About 3 tons, for a cooling load of 36,000 BTU/hr on a 95°F design day. That is one ton per 666 square feet in Madisonville's climate.
Is 20 BTU per square foot right for Madisonville?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Madisonville. For a single room here, plan on 18 BTU/hr per square foot.
What does central AC cost to run in Madisonville?
About $369 a year: 2,600 kWh at SEER2 14.3 and 14.2¢ per kWh, over 7 cooling months.