ACSizeCheck

What size AC for Murray, KY? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Murray needs

3 tons central AC or heat pump, about 36,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 17% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 666 square feet in this climate. For a single room, size by the room: 18 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Murray (1.2 mi away). Jul is the hottest month, averaging a high of 89.3°F and a low of 69°F, with about 46 days a year at 90°F or more. That gives a design temperature of 95°F against 75°F inside.

What it costs to run

About 2,415 kWh a year at SEER2 14.3, or roughly $343 at Kentucky's average residential rate of 14.2¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Murray

Of the 36,000 BTU/hr, 14,400 comes through walls, roof and windows on a 95°F afternoon (40%), 13,000 is sun on the house (36%), 2,120 is four people and their appliances, and 6,500 is moisture the coil has to wring out of Murray's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 29,520 BTU/hr before the moisture allowance.

Other house sizes in Murray

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft19,3001.5 tons2 tons
1,500 sq ft27,7002.5 tons2.5 tons
2,500 sq ft44,4004 tons5 tons
3,000 sq ft52,7005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,700 BTU/hr; a 350 sq ft living room needs about 6,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,800 BTU/hr.

Month by month in Murray

MonthAvg highCooling degree daysAC kWh
Jan45.6°F00
Feb50.4°F11
Mar60.6°F811
Apr71.4°F4261
May78.9°F148218
Jun86.3°F328484
Jul89.3°F439647
Aug88.8°F406599
Sep82.6°F217320
Oct71.2°F4667
Nov58.4°F46
Dec48.4°F00

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 959 hours a year at full output.

Murray against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Paris, TN22 mi93°F3 tons
Martin, TN35 mi96°F3.5 tons
Paducah, KY36 mi96°F3.5 tons
Union City, TN42 mi94°F3 tons
Hopkinsville, KY50 mi94°F3 tons
Clarksville, TN54 mi94°F3 tons

Of 42 Kentucky cities here, Murray has the 4th highest cooling load. The range runs from Versailles at 29,000 BTU/hr to Paducah at 36,900.

Where Murray's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Murray, 1.2 miles from the center of Murray at 492 ft above sea level. That is close enough that the station's summers are Murray's summers.

No other city in this set uses Murray, so this sizing is Murray's alone.

The sun over Murray in late July

At 36.61°N, the noon sun on 21 July stands 73.8° above the horizon over Murray and the day runs 14 h 08 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

18,567 people live in Murray, the 23rd largest of the 42 Kentucky cities sized on this site. Coordinates used: 36.6142, -88.3221.

Murray AC sizing questions

What size AC does a 2,000 sq ft house in Murray, KY need?

About 3 tons, for a cooling load of 36,000 BTU/hr on a 95°F design day. That is one ton per 666 square feet in Murray's climate.

Is 20 BTU per square foot right for Murray?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Murray. For a single room here, plan on 18 BTU/hr per square foot.

What does central AC cost to run in Murray?

About $343 a year: 2,415 kWh at SEER2 14.3 and 14.2¢ per kWh, over 5 cooling months.