What size AC for Clarksdale, MS? 3.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Clarksdale needs
3.5 tons central AC or heat pump, about 37,800 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 635 square feet in this climate. For a single room, size by the room: 18.9 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Clarksdale (0.8 mi away). Aug is the hottest month, averaging a high of 90.7°F and a low of 70.3°F, with about 67 days a year at 90°F or more. That gives a design temperature of 97°F against 75°F inside.
What it costs to run
About 3,079 kWh a year at SEER2 14.3, or roughly $464 at Mississippi's average residential rate of 15.06¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Clarksdale
Of the 37,800 BTU/hr, 15,840 comes through walls, roof and windows on a 97°F afternoon (42%), 13,000 is sun on the house (34%), 2,120 is four people and their appliances, and 6,800 is moisture the coil has to wring out of Clarksdale's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,960 BTU/hr before the moisture allowance.
Other house sizes in Clarksdale
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 20,200 | 2 tons | 2 tons |
| 1,500 sq ft | 29,000 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 46,600 | 4 tons | 5 tons |
| 3,000 sq ft | 55,400 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,300 BTU/hr.
Month by month in Clarksdale
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 50.3°F | 1 | 1 |
| Feb | 55.4°F | 2 | 3 |
| Mar | 63.5°F | 9 | 13 |
| Apr | 72.9°F | 57 | 84 |
| May | 81.4°F | 222 | 328 |
| Jun | 88.2°F | 410 | 604 |
| Jul | 90.4°F | 499 | 736 |
| Aug | 90.7°F | 480 | 708 |
| Sep | 86.2°F | 307 | 453 |
| Oct | 75.9°F | 91 | 134 |
| Nov | 63°F | 9 | 14 |
| Dec | 53.3°F | 1 | 2 |
Jul alone uses 24% of the year's cooling energy. The unit runs the equivalent of 1,166 hours a year at full output.
Clarksdale against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Cleveland, MS | 32 mi | 100°F | 3.5 tons |
| Greenwood, MS | 52 mi | 99°F | 3.5 tons |
| Grenada, MS | 52 mi | 97°F | 3.5 tons |
| Hernando, MS | 56 mi | 98°F | 3.5 tons |
| Forrest City, AR | 58 mi | 98°F | 3.5 tons |
| Oxford, MS | 60 mi | 98°F | 3.5 tons |
Of 41 Mississippi cities here, Clarksdale has the 37th highest cooling load. The range runs from Brookhaven at 36,900 BTU/hr to Columbus at 44,000.
Where Clarksdale's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Clarksdale, 0.8 miles from the center of Clarksdale at 173 ft above sea level. That is close enough that the station's summers are Clarksdale's summers.
No other city in this set uses Clarksdale, so this sizing is Clarksdale's alone.
The sun over Clarksdale in late July
At 34.19°N, the noon sun on 21 July stands 76.2° above the horizon over Clarksdale and the day runs 13 h 57 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
13,861 people live in Clarksdale, the 28th largest of the 41 Mississippi cities sized on this site. Coordinates used: 34.1938, -90.5686.
Clarksdale AC sizing questions
What size AC does a 2,000 sq ft house in Clarksdale, MS need?
About 3.5 tons, for a cooling load of 37,800 BTU/hr on a 97°F design day. That is one ton per 635 square feet in Clarksdale's climate.
Is 20 BTU per square foot right for Clarksdale?
The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Clarksdale. For a single room here, plan on 18.9 BTU/hr per square foot.
What does central AC cost to run in Clarksdale?
About $464 a year: 3,079 kWh at SEER2 14.3 and 15.06¢ per kWh, over 7 cooling months.