ACSizeCheck

What size AC for Cleveland, MS? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Cleveland needs

3.5 tons central AC or heat pump, about 40,400 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.4 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 594 square feet in this climate. For a single room, size by the room: 20.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cleveland (1 mi away). Aug is the hottest month, averaging a high of 93.1°F and a low of 71.6°F, with about 93 days a year at 90°F or more. That gives a design temperature of 100°F against 75°F inside.

What it costs to run

About 3,440 kWh a year at SEER2 14.3, or roughly $518 at Mississippi's average residential rate of 15.06¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Cleveland

Of the 40,400 BTU/hr, 18,000 comes through walls, roof and windows on a 100°F afternoon (45%), 13,000 is sun on the house (32%), 2,120 is four people and their appliances, and 7,300 is moisture the coil has to wring out of Cleveland's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,120 BTU/hr before the moisture allowance.

Other house sizes in Cleveland

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft21,5002 tons2 tons
1,500 sq ft31,0002.5 tons2.5 tons
2,500 sq ft49,9004 tons5 tons
3,000 sq ft59,3005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,000 BTU/hr; a 350 sq ft living room needs about 7,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,100 BTU/hr.

Month by month in Cleveland

MonthAvg highCooling degree daysAC kWh
Jan51.3°F11
Feb56.2°F35
Mar65.5°F1725
Apr74.6°F77114
May83.1°F254374
Jun89.6°F436643
Jul92°F532784
Aug93.1°F538793
Sep87.7°F344507
Oct77°F116171
Nov63.7°F1319
Dec54.1°F35

Aug alone uses 23% of the year's cooling energy. The unit runs the equivalent of 1,217 hours a year at full output.

Cleveland against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Greenville, MS31 mi99°F4 tons
Clarksdale, MS32 mi97°F3.5 tons
Greenwood, MS34 mi99°F3.5 tons
Grenada, MS53 mi97°F3.5 tons
Oxford, MS80 mi98°F3.5 tons
Pine Bluff, AR81 mi98°F3.5 tons

Of 41 Mississippi cities here, Cleveland has the 22nd highest cooling load. The range runs from Brookhaven at 36,900 BTU/hr to Columbus at 44,000.

Where Cleveland's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cleveland, 1 miles from the center of Cleveland at 138 ft above sea level. That is close enough that the station's summers are Cleveland's summers.

No other city in this set uses Cleveland, so this sizing is Cleveland's alone.

The sun over Cleveland in late July

At 33.74°N, the noon sun on 21 July stands 76.7° above the horizon over Cleveland and the day runs 13 h 55 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

10,183 people live in Cleveland, the 41st largest of the 41 Mississippi cities sized on this site. Coordinates used: 33.7440, -90.7285.

Cleveland AC sizing questions

What size AC does a 2,000 sq ft house in Cleveland, MS need?

About 3.5 tons, for a cooling load of 40,400 BTU/hr on a 100°F design day. That is one ton per 594 square feet in Cleveland's climate.

Is 20 BTU per square foot right for Cleveland?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Cleveland. For a single room here, plan on 20.2 BTU/hr per square foot.

What does central AC cost to run in Cleveland?

About $518 a year: 3,440 kWh at SEER2 14.3 and 15.06¢ per kWh, over 7 cooling months.