ACSizeCheck

What size AC for Oxford, MS? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Oxford needs

3.5 tons central AC or heat pump, about 38,700 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.2 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 621 square feet in this climate. For a single room, size by the room: 19.3 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at University (1.5 mi away). Jul is the hottest month, averaging a high of 91.3°F and a low of 70.2°F, with about 74 days a year at 90°F or more. That gives a design temperature of 98°F against 75°F inside.

What it costs to run

About 2,922 kWh a year at SEER2 14.3, or roughly $440 at Mississippi's average residential rate of 15.06¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Oxford

Of the 38,700 BTU/hr, 16,560 comes through walls, roof and windows on a 98°F afternoon (43%), 13,000 is sun on the house (34%), 2,120 is four people and their appliances, and 7,000 is moisture the coil has to wring out of Oxford's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 31,680 BTU/hr before the moisture allowance.

Other house sizes in Oxford

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft20,6002 tons2 tons
1,500 sq ft29,6002.5 tons2.5 tons
2,500 sq ft47,7004 tons5 tons
3,000 sq ft56,7005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,900 BTU/hr; a 350 sq ft living room needs about 6,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,600 BTU/hr.

Month by month in Oxford

MonthAvg highCooling degree daysAC kWh
Jan52.3°F11
Feb57.1°F23
Mar65.8°F1522
Apr74.2°F5987
May82°F203299
Jun88.6°F382562
Jul91.3°F488720
Aug91°F459676
Sep86.2°F281415
Oct76.1°F79116
Nov64.3°F1116
Dec55°F23

Jul alone uses 25% of the year's cooling energy. The unit runs the equivalent of 1,081 hours a year at full output.

Oxford against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Grenada, MS42 mi97°F3.5 tons
Hernando, MS43 mi98°F3.5 tons
Olive Branch, MS45 mi98°F3.5 tons
Tupelo, MS46 mi99°F4 tons
Southaven, MS48 mi98°F3.5 tons
Collierville, TN49 mi98°F3.5 tons

Of 41 Mississippi cities here, Oxford has the 34th highest cooling load. The range runs from Brookhaven at 36,900 BTU/hr to Columbus at 44,000.

Where Oxford's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is University, 1.5 miles from the center of Oxford at 408 ft above sea level. That is close enough that the station's summers are Oxford's summers.

No other city in this set uses University, so this sizing is Oxford's alone.

The sun over Oxford in late July

At 34.35°N, the noon sun on 21 July stands 76.0° above the horizon over Oxford and the day runs 13 h 58 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

26,801 people live in Oxford, the 12th largest of the 41 Mississippi cities sized on this site. Coordinates used: 34.3513, -89.5370.

Oxford AC sizing questions

What size AC does a 2,000 sq ft house in Oxford, MS need?

About 3.5 tons, for a cooling load of 38,700 BTU/hr on a 98°F design day. That is one ton per 621 square feet in Oxford's climate.

Is 20 BTU per square foot right for Oxford?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at University. For a single room here, plan on 19.3 BTU/hr per square foot.

What does central AC cost to run in Oxford?

About $440 a year: 2,922 kWh at SEER2 14.3 and 15.06¢ per kWh, over 7 cooling months.