ACSizeCheck

What size AC for Washington, IN? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Washington needs

3 tons central AC or heat pump, about 31,500 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 33% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 763 square feet in this climate. For a single room, size by the room: 15.7 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Washington 1 W (2.2 mi away). Jul is the hottest month, averaging a high of 87.4°F and a low of 66.8°F, with about 32 days a year at 90°F or more. That gives a design temperature of 92°F against 75°F inside.

What it costs to run

About 1,904 kWh a year at SEER2 14.3, or roughly $324 at Indiana's average residential rate of 17.04¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Washington

Of the 31,500 BTU/hr, 12,240 comes through walls, roof and windows on a 92°F afternoon (39%), 13,000 is sun on the house (41%), 2,120 is four people and their appliances, and 4,100 is moisture the coil has to wring out of Washington's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 27,360 BTU/hr before the moisture allowance.

Other house sizes in Washington

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft17,0001.5 tons2 tons
1,500 sq ft24,2002 tons2.5 tons
2,500 sq ft38,7003.5 tons5 tons
3,000 sq ft46,0004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,400 BTU/hr; a 350 sq ft living room needs about 5,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,400 BTU/hr.

Month by month in Washington

MonthAvg highCooling degree daysAC kWh
Jan40.4°F00
Feb45.6°F01
Mar56.5°F57
Apr68.5°F2839
May77.4°F132183
Jun85°F289401
Jul87.4°F375521
Aug86.3°F333463
Sep81.1°F169234
Oct69.9°F3852
Nov55.6°F22
Dec44.7°F00

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 865 hours a year at full output.

Washington against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Vincennes, IN19 mi93°F3 tons
Jasper, IN22 mi98°F3 tons
Bedford, IN39 mi88°F2.5 tons
Bloomington, IN49 mi90°F2.5 tons
Evansville, IN51 mi94°F3 tons
Terre Haute, IN57 mi91°F2.5 tons

Of 88 Indiana cities here, Washington has the 9th highest cooling load. The range runs from Auburn at 24,100 BTU/hr to Jasper at 36,400.

Where Washington's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Washington 1 W, 2.2 miles from the center of Washington at 482 ft above sea level. That is close enough that the station's summers are Washington's summers.

No other city in this set uses Washington 1 W, so this sizing is Washington's alone.

The sun over Washington in late July

At 38.66°N, the noon sun on 21 July stands 71.7° above the horizon over Washington and the day runs 14 h 18 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

12,881 people live in Washington, the 70th largest of the 88 Indiana cities sized on this site. Coordinates used: 38.6582, -87.1604.

Washington AC sizing questions

What size AC does a 2,000 sq ft house in Washington, IN need?

About 3 tons, for a cooling load of 31,500 BTU/hr on a 92°F design day. That is one ton per 763 square feet in Washington's climate.

Is 20 BTU per square foot right for Washington?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Washington 1 W. For a single room here, plan on 15.7 BTU/hr per square foot.

What does central AC cost to run in Washington?

About $324 a year: 1,904 kWh at SEER2 14.3 and 17.04¢ per kWh, over 5 cooling months.