What size AC for Jasper, IN? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Jasper needs

3 tons central AC or heat pump, about 36,400 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 15% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 659 square feet in this climate. For a single room, size by the room: 18.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Patoka Lake (13.2 mi away). Jul is the hottest month, averaging a high of 91.7°F and a low of 67.2°F, with about 73 days a year at 90°F or more. That gives a design temperature of 98°F against 75°F inside.

What it costs to run

About 2,136 kWh a year at SEER2 14.3, or roughly $364 at Indiana's average residential rate of 17.04¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Jasper

Of the 36,400 BTU/hr, 16,560 comes through walls, roof and windows on a 98°F afternoon (45%), 13,000 is sun on the house (36%), 2,120 is four people and their appliances, and 4,800 is moisture the coil has to wring out of Jasper's summer air (13%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 31,680 BTU/hr before the moisture allowance.

Other house sizes in Jasper

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft19,4001.5 tons2 tons
1,500 sq ft27,9002.5 tons2.5 tons
2,500 sq ft44,9004 tons5 tons
3,000 sq ft53,4005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,700 BTU/hr; a 350 sq ft living room needs about 6,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,900 BTU/hr.

Month by month in Jasper

MonthAvg highCooling degree daysAC kWh
Jan42.4°F00
Feb46.7°F00
Mar57.2°F00
Apr68.6°F1217
May78.2°F133185
Jun87.1°F309429
Jul91.7°F447621
Aug89.7°F383532
Sep83.4°F200278
Oct73°F4968
Nov57.9°F46
Dec47°F00

Jul alone uses 29% of the year's cooling energy. The unit runs the equivalent of 839 hours a year at full output.

Jasper against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Washington, IN22 mi92°F3 tons
Vincennes, IN36 mi93°F3 tons
Bedford, IN40 mi88°F2.5 tons
Evansville, IN43 mi94°F3 tons
Owensboro, KY45 mi94°F3 tons
Henderson, KY52 mi94°F3 tons

Of 88 Indiana cities here, Jasper has the highest cooling load. The range runs from Auburn at 24,100 BTU/hr to Jasper at 36,400.

Where Jasper's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Patoka Lake, 13.2 miles from the center of Jasper at 561 ft above sea level. That is close enough that the station's summers are Jasper's summers.

No other city in this set uses Patoka Lake, so this sizing is Jasper's alone.

The sun over Jasper in late July

At 38.39°N, the noon sun on 21 July stands 72.0° above the horizon over Jasper and the day runs 14 h 17 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

16,967 people live in Jasper, the 53rd largest of the 88 Indiana cities sized on this site. Coordinates used: 38.3932, -86.9406.

Jasper AC sizing questions

What size AC does a 2,000 sq ft house in Jasper, IN need?

About 3 tons, for a cooling load of 36,400 BTU/hr on a 98°F design day. That is one ton per 659 square feet in Jasper's climate.

Is 20 BTU per square foot right for Jasper?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Patoka Lake. For a single room here, plan on 18.2 BTU/hr per square foot.

What does central AC cost to run in Jasper?

About $364 a year: 2,136 kWh at SEER2 14.3 and 17.04¢ per kWh, over 5 cooling months.