ACSizeCheck

What size AC for Bloomington, IN? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Bloomington needs

2.5 tons central AC or heat pump, about 29,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 41% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 805 square feet in this climate. For a single room, size by the room: 14.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Bloomington Monroe County Airport (5.2 mi away). Jul is the hottest month, averaging a high of 85°F and a low of 64.3°F, with about 20 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.

What it costs to run

About 1,426 kWh a year at SEER2 14.3, or roughly $243 at Indiana's average residential rate of 17.04¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Bloomington

Of the 29,800 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (36%), 13,000 is sun on the house (44%), 2,120 is four people and their appliances, and 3,900 is moisture the coil has to wring out of Bloomington's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.

Other house sizes in Bloomington

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,1001.5 tons2 tons
1,500 sq ft23,0002 tons2.5 tons
2,500 sq ft36,7003.5 tons5 tons
3,000 sq ft43,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,900 BTU/hr.

Month by month in Bloomington

MonthAvg highCooling degree daysAC kWh
Jan38.7°F00
Feb42.9°F00
Mar53.6°F35
Apr65.6°F1724
May74.4°F85119
Jun82.3°F224311
Jul85°F301418
Aug84.4°F263365
Sep78.3°F113157
Oct66.8°F1927
Nov53.3°F11
Dec42.2°F00

Jul alone uses 29% of the year's cooling energy. The unit runs the equivalent of 684 hours a year at full output.

Bloomington against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Martinsville, IN18 mi88°F2.5 tons
Bedford, IN21 mi88°F2.5 tons
Bargersville, IN31 mi90°F2.5 tons
Mooresville, IN31 mi90°F2.5 tons
Columbus, IN32 mi91°F2.5 tons
Franklin, IN34 mi91°F2.5 tons

Of 88 Indiana cities here, Bloomington has the 18th highest cooling load. The range runs from Auburn at 24,100 BTU/hr to Jasper at 36,400.

Where Bloomington's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Bloomington Monroe County Airport, 5.2 miles from the center of Bloomington at 831 ft above sea level. That is close enough that the station's summers are Bloomington's summers.

No other city in this set uses Bloomington Monroe County Airport, so this sizing is Bloomington's alone.

The sun over Bloomington in late July

At 39.16°N, the noon sun on 21 July stands 71.2° above the horizon over Bloomington and the day runs 14 h 21 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

79,986 people live in Bloomington, the 7th largest of the 88 Indiana cities sized on this site. Coordinates used: 39.1637, -86.5243.

Bloomington AC sizing questions

What size AC does a 2,000 sq ft house in Bloomington, IN need?

About 2.5 tons, for a cooling load of 29,800 BTU/hr on a 90°F design day. That is one ton per 805 square feet in Bloomington's climate.

Is 20 BTU per square foot right for Bloomington?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Bloomington Monroe County Airport. For a single room here, plan on 14.9 BTU/hr per square foot.

What does central AC cost to run in Bloomington?

About $243 a year: 1,426 kWh at SEER2 14.3 and 17.04¢ per kWh, over 5 cooling months.