What size AC for Streamwood, IL? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Streamwood needs
2.5 tons central AC or heat pump, about 26,400 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 59% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 908 square feet in this climate. For a single room, size by the room: 13.2 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Chicago W Chicago Dupage Airport (9.4 mi away). Jul is the hottest month, averaging a high of 84°F and a low of 63.3°F, with about 15 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.
What it costs to run
About 1,073 kWh a year at SEER2 14.3, or roughly $206 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 4 months of the year here.
What drives the load in Streamwood
Of the 26,400 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (35%), 13,000 is sun on the house (49%), 2,120 is four people and their appliances, and 2,000 is moisture the coil has to wring out of Streamwood's summer air (8%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.
Other house sizes in Streamwood
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 14,400 | 1.5 tons | 2 tons |
| 1,500 sq ft | 20,400 | 2 tons | 2.5 tons |
| 2,500 sq ft | 32,500 | 3 tons | 5 tons |
| 3,000 sq ft | 38,500 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.
Month by month in Streamwood
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 30.5°F | 0 | 0 |
| Feb | 34.9°F | 0 | 0 |
| Mar | 47°F | 2 | 2 |
| Apr | 59.6°F | 5 | 6 |
| May | 70.9°F | 50 | 65 |
| Jun | 80.6°F | 175 | 228 |
| Jul | 84°F | 272 | 355 |
| Aug | 82°F | 221 | 288 |
| Sep | 75.5°F | 88 | 115 |
| Oct | 62.4°F | 11 | 14 |
| Nov | 47.7°F | 0 | 0 |
| Dec | 35.4°F | 0 | 0 |
Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 580 hours a year at full output.
Streamwood against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Hanover Park, IL | 3 mi | 88°F | 2.5 tons |
| Hoffman Estates, IL | 3 mi | 88°F | 2.5 tons |
| Bartlett, IL | 4 mi | 88°F | 2.5 tons |
| Schaumburg, IL | 5 mi | 89°F | 2.5 tons |
| Roselle, IL | 5 mi | 89°F | 2.5 tons |
| Bloomingdale, IL | 7 mi | 89°F | 2.5 tons |
Of 225 Illinois cities here, Streamwood has the 184th highest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.
Where Streamwood's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Chicago W Chicago Dupage Airport, 9.4 miles from the center of Streamwood at 749 ft above sea level. That is close enough that the station's summers are Streamwood's summers.
23 other cities use the same station and get the same climate inputs. The closest to Streamwood: Hanover Park (3 mi away, 8.1 mi from the station), Hoffman Estates (3 mi away, 12.8 mi from the station), Bartlett (4 mi away, 5.8 mi from the station), Carol Stream (7 mi away, 6.3 mi from the station), South Elgin (7 mi away, 7.3 mi from the station). Streamwood is farther from the station than 12 of them.
The sun over Streamwood in late July
At 42.02°N, the noon sun on 21 July stands 68.4° above the horizon over Streamwood and the day runs 14 h 37 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
38,360 people live in Streamwood, the 47th largest of the 225 Illinois cities sized on this site. Coordinates used: 42.0206, -88.1778.
Streamwood AC sizing questions
What size AC does a 2,000 sq ft house in Streamwood, IL need?
About 2.5 tons, for a cooling load of 26,400 BTU/hr on a 88°F design day. That is one ton per 908 square feet in Streamwood's climate.
Is 20 BTU per square foot right for Streamwood?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Chicago W Chicago Dupage Airport. For a single room here, plan on 13.2 BTU/hr per square foot.
What does central AC cost to run in Streamwood?
About $206 a year: 1,073 kWh at SEER2 14.3 and 19.23¢ per kWh, over 4 cooling months.