ACSizeCheck

What size AC for Bartlett, IL? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Bartlett needs

2.5 tons central AC or heat pump, about 26,400 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 59% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 908 square feet in this climate. For a single room, size by the room: 13.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Chicago W Chicago Dupage Airport (5.8 mi away). Jul is the hottest month, averaging a high of 84°F and a low of 63.3°F, with about 15 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.

What it costs to run

About 1,073 kWh a year at SEER2 14.3, or roughly $206 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Bartlett

Of the 26,400 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (35%), 13,000 is sun on the house (49%), 2,120 is four people and their appliances, and 2,000 is moisture the coil has to wring out of Bartlett's summer air (8%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.

Other house sizes in Bartlett

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,4001.5 tons2 tons
1,500 sq ft20,4002 tons2.5 tons
2,500 sq ft32,5003 tons5 tons
3,000 sq ft38,5003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.

Month by month in Bartlett

MonthAvg highCooling degree daysAC kWh
Jan30.5°F00
Feb34.9°F00
Mar47°F22
Apr59.6°F56
May70.9°F5065
Jun80.6°F175228
Jul84°F272355
Aug82°F221288
Sep75.5°F88115
Oct62.4°F1114
Nov47.7°F00
Dec35.4°F00

Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 580 hours a year at full output.

Bartlett against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Hanover Park, IL2 mi88°F2.5 tons
Carol Stream, IL4 mi88°F2.5 tons
Streamwood, IL4 mi88°F2.5 tons
Bloomingdale, IL5 mi89°F2.5 tons
Roselle, IL5 mi89°F2.5 tons
West Chicago, IL5 mi88°F2.5 tons

Of 225 Illinois cities here, Bartlett has the 182nd highest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.

Where Bartlett's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Chicago W Chicago Dupage Airport, 5.8 miles from the center of Bartlett at 749 ft above sea level. That is close enough that the station's summers are Bartlett's summers.

23 other cities use the same station and get the same climate inputs. The closest to Bartlett: Hanover Park (2 mi away, 8.1 mi from the station), Carol Stream (4 mi away, 6.3 mi from the station), Streamwood (4 mi away, 9.4 mi from the station), West Chicago (5 mi away, 1.5 mi from the station), Winfield (6 mi away, 5.2 mi from the station). Bartlett is farther from the station than 5 of them.

The sun over Bartlett in late July

At 41.96°N, the noon sun on 21 July stands 68.4° above the horizon over Bartlett and the day runs 14 h 36 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

40,718 people live in Bartlett, the 39th largest of the 225 Illinois cities sized on this site. Coordinates used: 41.9606, -88.1777.

Bartlett AC sizing questions

What size AC does a 2,000 sq ft house in Bartlett, IL need?

About 2.5 tons, for a cooling load of 26,400 BTU/hr on a 88°F design day. That is one ton per 908 square feet in Bartlett's climate.

Is 20 BTU per square foot right for Bartlett?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Chicago W Chicago Dupage Airport. For a single room here, plan on 13.2 BTU/hr per square foot.

What does central AC cost to run in Bartlett?

About $206 a year: 1,073 kWh at SEER2 14.3 and 19.23¢ per kWh, over 4 cooling months.