What size AC for Schaumburg, IL? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Schaumburg needs
2.5 tons central AC or heat pump, about 29,000 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 45% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 828 square feet in this climate. For a single room, size by the room: 14.5 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Chicago Ohare International Airport (9.1 mi away). Jul is the hottest month, averaging a high of 84.5°F and a low of 66.4°F, with about 17 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.
What it costs to run
About 1,394 kWh a year at SEER2 14.3, or roughly $268 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Schaumburg
Of the 29,000 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (35%), 13,000 is sun on the house (45%), 2,120 is four people and their appliances, and 3,800 is moisture the coil has to wring out of Schaumburg's summer air (13%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.
Other house sizes in Schaumburg
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 15,700 | 1.5 tons | 2 tons |
| 1,500 sq ft | 22,300 | 2 tons | 2.5 tons |
| 2,500 sq ft | 35,600 | 3 tons | 5 tons |
| 3,000 sq ft | 42,300 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,700 BTU/hr.
Month by month in Schaumburg
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 31.6°F | 0 | 0 |
| Feb | 35.7°F | 0 | 0 |
| Mar | 47°F | 2 | 3 |
| Apr | 59°F | 8 | 11 |
| May | 70.5°F | 60 | 83 |
| Jun | 80.4°F | 199 | 277 |
| Jul | 84.5°F | 326 | 452 |
| Aug | 82.5°F | 277 | 385 |
| Sep | 75.5°F | 116 | 161 |
| Oct | 62.7°F | 15 | 21 |
| Nov | 48.4°F | 0 | 1 |
| Dec | 36.6°F | 0 | 0 |
Jul alone uses 32% of the year's cooling energy. The unit runs the equivalent of 688 hours a year at full output.
Schaumburg against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Roselle, IL | 3 mi | 89°F | 2.5 tons |
| Hoffman Estates, IL | 4 mi | 88°F | 2.5 tons |
| Rolling Meadows, IL | 4 mi | 89°F | 2.5 tons |
| Hanover Park, IL | 4 mi | 88°F | 2.5 tons |
| Streamwood, IL | 5 mi | 88°F | 2.5 tons |
| Elk Grove Village, IL | 5 mi | 89°F | 2.5 tons |
Of 225 Illinois cities here, Schaumburg has the 101st highest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.
Where Schaumburg's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Chicago Ohare International Airport, 9.1 miles from the center of Schaumburg at 672 ft above sea level. That is close enough that the station's summers are Schaumburg's summers.
27 other cities use the same station and get the same climate inputs. The closest to Schaumburg: Roselle (3 mi away, 8 mi from the station), Elk Grove Village (5 mi away, 4.4 mi from the station), Bloomingdale (5 mi away, 8.1 mi from the station), Wood Dale (7 mi away, 2.6 mi from the station), Glendale Heights (8 mi away, 8.1 mi from the station). Schaumburg is farther from the station than 24 of them.
The sun over Schaumburg in late July
At 42.03°N, the noon sun on 21 July stands 68.4° above the horizon over Schaumburg and the day runs 14 h 37 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
77,099 people live in Schaumburg, the 13th largest of the 225 Illinois cities sized on this site. Coordinates used: 42.0289, -88.0838.
Schaumburg AC sizing questions
What size AC does a 2,000 sq ft house in Schaumburg, IL need?
About 2.5 tons, for a cooling load of 29,000 BTU/hr on a 89°F design day. That is one ton per 828 square feet in Schaumburg's climate.
Is 20 BTU per square foot right for Schaumburg?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Chicago Ohare International Airport. For a single room here, plan on 14.5 BTU/hr per square foot.
What does central AC cost to run in Schaumburg?
About $268 a year: 1,394 kWh at SEER2 14.3 and 19.23¢ per kWh, over 5 cooling months.