ACSizeCheck

What size AC for Bowling Green, KY? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Bowling Green needs

3 tons central AC or heat pump, about 36,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 17% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 666 square feet in this climate. For a single room, size by the room: 18 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Bowling Green Warren County Airport (1 mi away). Jul is the hottest month, averaging a high of 89.7°F and a low of 69.7°F, with about 47 days a year at 90°F or more. That gives a design temperature of 95°F against 75°F inside.

What it costs to run

About 2,470 kWh a year at SEER2 14.3, or roughly $351 at Kentucky's average residential rate of 14.2¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Bowling Green

Of the 36,000 BTU/hr, 14,400 comes through walls, roof and windows on a 95°F afternoon (40%), 13,000 is sun on the house (36%), 2,120 is four people and their appliances, and 6,500 is moisture the coil has to wring out of Bowling Green's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 29,520 BTU/hr before the moisture allowance.

Other house sizes in Bowling Green

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft19,3001.5 tons2 tons
1,500 sq ft27,7002.5 tons2.5 tons
2,500 sq ft44,4004 tons5 tons
3,000 sq ft52,7005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,700 BTU/hr; a 350 sq ft living room needs about 6,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,800 BTU/hr.

Month by month in Bowling Green

MonthAvg highCooling degree daysAC kWh
Jan46.2°F00
Feb51°F11
Mar60.1°F710
Apr70.7°F4059
May78.7°F150221
Jun86.6°F336495
Jul89.7°F456672
Aug89.3°F419617
Sep83°F217320
Oct72°F4668
Nov59.2°F46
Dec49.4°F11

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 981 hours a year at full output.

Bowling Green against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Franklin, KY19 mi95°F3 tons
Portland, TN27 mi94°F3 tons
Glasgow, KY28 mi96°F3 tons
White House, TN38 mi94°F3 tons
Gallatin, TN41 mi97°F3.5 tons
Springfield, TN41 mi94°F3 tons

Of 42 Kentucky cities here, Bowling Green has the 2nd highest cooling load. The range runs from Versailles at 29,000 BTU/hr to Paducah at 36,900.

Where Bowling Green's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Bowling Green Warren County Airport, 1 miles from the center of Bowling Green at 523 ft above sea level. That is close enough that the station's summers are Bowling Green's summers.

1 other city uses the same station and get the same climate inputs. The closest to Bowling Green: Franklin (19 mi away, 18.6 mi from the station). Bowling Green sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Bowling Green in late July

At 36.98°N, the noon sun on 21 July stands 73.4° above the horizon over Bowling Green and the day runs 14 h 10 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

79,076 people live in Bowling Green, the 3rd largest of the 42 Kentucky cities sized on this site. Coordinates used: 36.9768, -86.4337.

Bowling Green AC sizing questions

What size AC does a 2,000 sq ft house in Bowling Green, KY need?

About 3 tons, for a cooling load of 36,000 BTU/hr on a 95°F design day. That is one ton per 666 square feet in Bowling Green's climate.

Is 20 BTU per square foot right for Bowling Green?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Bowling Green Warren County Airport. For a single room here, plan on 18 BTU/hr per square foot.

What does central AC cost to run in Bowling Green?

About $351 a year: 2,470 kWh at SEER2 14.3 and 14.2¢ per kWh, over 5 cooling months.