What size AC for La Grande, OR? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in La Grande needs
2.5 tons central AC or heat pump, about 28,500 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 48% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 843 square feet in this climate. For a single room, size by the room: 14.2 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at La Grande (0.8 mi away). Aug is the hottest month, averaging a high of 87°F and a low of 52.8°F, with about 31 days a year at 90°F or more. That gives a design temperature of 92°F against 75°F inside.
What it costs to run
About 599 kWh a year at SEER2 14.3, or roughly $93 at Oregon's average residential rate of 15.46¢ per kWh. Cooling runs 2 months of the year here.
What drives the load in La Grande
Of the 28,500 BTU/hr, 12,240 comes through walls, roof and windows on a 92°F afternoon (43%), 13,000 is sun on the house (46%), 2,120 is four people and their appliances, and 1,100 is moisture the coil has to wring out of La Grande's summer air (4%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 27,360 BTU/hr before the moisture allowance.
Other house sizes in La Grande
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 15,300 | 1.5 tons | 2 tons |
| 1,500 sq ft | 21,900 | 2 tons | 2.5 tons |
| 2,500 sq ft | 35,000 | 3 tons | 5 tons |
| 3,000 sq ft | 41,600 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 5,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,500 BTU/hr.
Month by month in La Grande
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 39.3°F | 0 | 0 |
| Feb | 44°F | 0 | 0 |
| Mar | 51.6°F | 0 | 0 |
| Apr | 58.7°F | 0 | 0 |
| May | 67.8°F | 10 | 12 |
| Jun | 74.9°F | 49 | 62 |
| Jul | 86.2°F | 193 | 243 |
| Aug | 87°F | 181 | 228 |
| Sep | 77.3°F | 43 | 54 |
| Oct | 62.4°F | 0 | 1 |
| Nov | 47.7°F | 0 | 0 |
| Dec | 38.7°F | 0 | 0 |
Jul alone uses 41% of the year's cooling energy. The unit runs the equivalent of 301 hours a year at full output.
La Grande against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Baker City, OR | 40 mi | 93°F | 2.5 tons |
| Pendleton, OR | 43 mi | 94°F | 2.5 tons |
| Walla Walla, WA | 53 mi | 96°F | 3 tons |
| Hermiston, OR | 68 mi | 98°F | 3 tons |
| Kennewick, WA | 80 mi | 98°F | 3 tons |
| Pasco, WA | 82 mi | 98°F | 3 tons |
Of 57 Oregon cities here, La Grande has the 12th highest cooling load. The range runs from North Bend at 15,700 BTU/hr to Ontario at 36,500.
Where La Grande's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is La Grande, 0.8 miles from the center of La Grande at 2,755 ft above sea level. That is close enough that the station's summers are La Grande's summers.
No other city in this set uses La Grande, so this sizing is La Grande's alone.
The sun over La Grande in late July
At 45.32°N, the noon sun on 21 July stands 65.1° above the horizon over La Grande and the day runs 14 h 57 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
13,058 people live in La Grande, the 42nd largest of the 57 Oregon cities sized on this site. Coordinates used: 45.3245, -118.0869.
La Grande AC sizing questions
What size AC does a 2,000 sq ft house in La Grande, OR need?
About 2.5 tons, for a cooling load of 28,500 BTU/hr on a 92°F design day. That is one ton per 843 square feet in La Grande's climate.
Is 20 BTU per square foot right for La Grande?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at La Grande. For a single room here, plan on 14.2 BTU/hr per square foot.
What does central AC cost to run in La Grande?
About $93 a year: 599 kWh at SEER2 14.3 and 15.46¢ per kWh, over 2 cooling months.