What size AC for Pendleton, OR? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Pendleton needs
2.5 tons central AC or heat pump, about 30,000 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 40% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 801 square feet in this climate. For a single room, size by the room: 15 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Pendleton (1.9 mi away). Jul is the hottest month, averaging a high of 89.2°F and a low of 56.7°F, with about 37 days a year at 90°F or more. That gives a design temperature of 94°F against 75°F inside.
What it costs to run
About 799 kWh a year at SEER2 14.3, or roughly $124 at Oregon's average residential rate of 15.46¢ per kWh. Cooling runs 4 months of the year here.
What drives the load in Pendleton
Of the 30,000 BTU/hr, 13,680 comes through walls, roof and windows on a 94°F afternoon (46%), 13,000 is sun on the house (43%), 2,120 is four people and their appliances, and 1,200 is moisture the coil has to wring out of Pendleton's summer air (4%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 28,800 BTU/hr before the moisture allowance.
Other house sizes in Pendleton
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 16,100 | 1.5 tons | 2 tons |
| 1,500 sq ft | 23,000 | 2 tons | 2.5 tons |
| 2,500 sq ft | 36,900 | 3.5 tons | 5 tons |
| 3,000 sq ft | 43,800 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,300 BTU/hr; a 350 sq ft living room needs about 5,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,000 BTU/hr.
Month by month in Pendleton
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 41.7°F | 0 | 0 |
| Feb | 46.4°F | 0 | 0 |
| Mar | 55°F | 0 | 0 |
| Apr | 61.8°F | 1 | 1 |
| May | 70.9°F | 20 | 25 |
| Jun | 78.4°F | 73 | 92 |
| Jul | 89.2°F | 255 | 320 |
| Aug | 87.6°F | 223 | 280 |
| Sep | 78°F | 62 | 78 |
| Oct | 63.5°F | 3 | 3 |
| Nov | 49.1°F | 0 | 0 |
| Dec | 40.8°F | 0 | 0 |
Jul alone uses 40% of the year's cooling energy. The unit runs the equivalent of 382 hours a year at full output.
Pendleton against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Hermiston, OR | 25 mi | 98°F | 3 tons |
| Walla Walla, WA | 36 mi | 96°F | 3 tons |
| Kennewick, WA | 40 mi | 98°F | 3 tons |
| La Grande, OR | 43 mi | 92°F | 2.5 tons |
| Pasco, WA | 43 mi | 98°F | 3 tons |
| Richland, WA | 48 mi | 98°F | 3 tons |
Of 57 Oregon cities here, Pendleton has the 7th highest cooling load. The range runs from North Bend at 15,700 BTU/hr to Ontario at 36,500.
Where Pendleton's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Pendleton, 1.9 miles from the center of Pendleton at 1,580 ft above sea level. That is close enough that the station's summers are Pendleton's summers.
No other city in this set uses Pendleton, so this sizing is Pendleton's alone.
The sun over Pendleton in late July
At 45.68°N, the noon sun on 21 July stands 64.7° above the horizon over Pendleton and the day runs 14 h 59 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
17,026 people live in Pendleton, the 36th largest of the 57 Oregon cities sized on this site. Coordinates used: 45.6756, -118.8195.
Pendleton AC sizing questions
What size AC does a 2,000 sq ft house in Pendleton, OR need?
About 2.5 tons, for a cooling load of 30,000 BTU/hr on a 94°F design day. That is one ton per 801 square feet in Pendleton's climate.
Is 20 BTU per square foot right for Pendleton?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Pendleton. For a single room here, plan on 15 BTU/hr per square foot.
What does central AC cost to run in Pendleton?
About $124 a year: 799 kWh at SEER2 14.3 and 15.46¢ per kWh, over 4 cooling months.