What size AC for Findlay, OH? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Findlay needs
2.5 tons central AC or heat pump, about 29,800 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 41% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 805 square feet in this climate. For a single room, size by the room: 14.9 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Findlay Airport (2.8 mi away). Jul is the hottest month, averaging a high of 85.4°F and a low of 64.4°F, with about 17 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.
What it costs to run
About 1,397 kWh a year at SEER2 14.3, or roughly $263 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Findlay
Of the 29,800 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (36%), 13,000 is sun on the house (44%), 2,120 is four people and their appliances, and 3,900 is moisture the coil has to wring out of Findlay's summer air (13%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.
Other house sizes in Findlay
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 16,100 | 1.5 tons | 2 tons |
| 1,500 sq ft | 23,000 | 2 tons | 2.5 tons |
| 2,500 sq ft | 36,700 | 3.5 tons | 5 tons |
| 3,000 sq ft | 43,500 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,900 BTU/hr.
Month by month in Findlay
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 35.1°F | 0 | 0 |
| Feb | 38.4°F | 0 | 0 |
| Mar | 48.9°F | 2 | 2 |
| Apr | 62.2°F | 11 | 15 |
| May | 73.3°F | 77 | 107 |
| Jun | 82.1°F | 221 | 306 |
| Jul | 85.4°F | 308 | 428 |
| Aug | 83.5°F | 250 | 348 |
| Sep | 77.7°F | 117 | 162 |
| Oct | 65.2°F | 19 | 27 |
| Nov | 51.4°F | 1 | 1 |
| Dec | 39.8°F | 0 | 0 |
Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 670 hours a year at full output.
Findlay against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Fostoria, OH | 14 mi | 90°F | 2.5 tons |
| Bowling Green, OH | 23 mi | 89°F | 2.5 tons |
| Tiffin, OH | 24 mi | 88°F | 2.5 tons |
| Lima, OH | 33 mi | 88°F | 2.5 tons |
| Perrysburg, OH | 34 mi | 89°F | 2.5 tons |
| Fremont, OH | 35 mi | 90°F | 2.5 tons |
Of 176 Ohio cities here, Findlay has the 31st highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.
Where Findlay's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Findlay Airport, 2.8 miles from the center of Findlay at 809 ft above sea level. That is close enough that the station's summers are Findlay's summers.
1 other city uses the same station and get the same climate inputs. The closest to Findlay: Fostoria (14 mi away, 16.7 mi from the station). Findlay sits closer to the station than any of them, so its numbers are the best measured of the group.
The sun over Findlay in late July
At 41.05°N, the noon sun on 21 July stands 69.4° above the horizon over Findlay and the day runs 14 h 31 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
40,343 people live in Findlay, the 32nd largest of the 176 Ohio cities sized on this site. Coordinates used: 41.0474, -83.6381.
Findlay AC sizing questions
What size AC does a 2,000 sq ft house in Findlay, OH need?
About 2.5 tons, for a cooling load of 29,800 BTU/hr on a 90°F design day. That is one ton per 805 square feet in Findlay's climate.
Is 20 BTU per square foot right for Findlay?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Findlay Airport. For a single room here, plan on 14.9 BTU/hr per square foot.
What does central AC cost to run in Findlay?
About $263 a year: 1,397 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.