ACSizeCheck

What size AC for Connersville, IN? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Connersville needs

2 tons central AC or heat pump, about 25,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 64% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 935 square feet in this climate. For a single room, size by the room: 12.8 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cambridge City 3 N (14.6 mi away). Jul is the hottest month, averaging a high of 82.4°F and a low of 60.7°F, with about 6 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 835 kWh a year at SEER2 14.3, or roughly $142 at Indiana's average residential rate of 17.04¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Connersville

Of the 25,700 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (34%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 1,900 is moisture the coil has to wring out of Connersville's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Connersville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,0001.5 tons2 tons
1,500 sq ft19,8001.5 tons2.5 tons
2,500 sq ft31,5003 tons5 tons
3,000 sq ft37,3003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,700 BTU/hr.

Month by month in Connersville

MonthAvg highCooling degree daysAC kWh
Jan33.8°F00
Feb38°F00
Mar48.6°F01
Apr61.2°F56
May71.2°F4255
Jun79°F143186
Jul82.4°F210273
Aug81.3°F169220
Sep76.4°F6685
Oct64°F57
Nov50.4°F00
Dec38.6°F00

Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 465 hours a year at full output.

Connersville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Richmond, IN18 mi89°F2.5 tons
New Castle, IN22 mi87°F2 tons
Oxford, OH24 mi92°F3 tons
Greensburg, IN29 mi89°F2.5 tons
Harrison, OH34 mi91°F2.5 tons
Shelbyville, IN35 mi91°F2.5 tons

Of 88 Indiana cities here, Connersville has the 86th highest cooling load. The range runs from Auburn at 24,100 BTU/hr to Jasper at 36,400.

Where Connersville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cambridge City 3 N, 14.6 miles from the center of Connersville at 1,000 ft above sea level. That is close enough that the station's summers are Connersville's summers.

No other city in this set uses Cambridge City 3 N, so this sizing is Connersville's alone.

The sun over Connersville in late July

At 39.66°N, the noon sun on 21 July stands 70.7° above the horizon over Connersville and the day runs 14 h 24 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

13,282 people live in Connersville, the 68th largest of the 88 Indiana cities sized on this site. Coordinates used: 39.6580, -85.1417.

Connersville AC sizing questions

What size AC does a 2,000 sq ft house in Connersville, IN need?

About 2 tons, for a cooling load of 25,700 BTU/hr on a 87°F design day. That is one ton per 935 square feet in Connersville's climate.

Is 20 BTU per square foot right for Connersville?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Cambridge City 3 N. For a single room here, plan on 12.8 BTU/hr per square foot.

What does central AC cost to run in Connersville?

About $142 a year: 835 kWh at SEER2 14.3 and 17.04¢ per kWh, over 4 cooling months.