ACSizeCheck

What size AC for Greensburg, IN? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Greensburg needs

2.5 tons central AC or heat pump, about 29,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 45% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 828 square feet in this climate. For a single room, size by the room: 14.5 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Greensburg (0.7 mi away). Jul is the hottest month, averaging a high of 84.5°F and a low of 66.3°F, with about 16 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.

What it costs to run

About 1,558 kWh a year at SEER2 14.3, or roughly $265 at Indiana's average residential rate of 17.04¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Greensburg

Of the 29,000 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (35%), 13,000 is sun on the house (45%), 2,120 is four people and their appliances, and 3,800 is moisture the coil has to wring out of Greensburg's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.

Other house sizes in Greensburg

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft15,7001.5 tons2 tons
1,500 sq ft22,3002 tons2.5 tons
2,500 sq ft35,6003 tons5 tons
3,000 sq ft42,3004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,700 BTU/hr.

Month by month in Greensburg

MonthAvg highCooling degree daysAC kWh
Jan36.2°F00
Feb40.6°F00
Mar51°F34
Apr63.7°F1724
May73.5°F97135
Jun81.6°F238331
Jul84.5°F323449
Aug83.4°F279388
Sep77.7°F138191
Oct65.8°F2433
Nov52°F11
Dec40.7°F00

Jul alone uses 29% of the year's cooling energy. The unit runs the equivalent of 769 hours a year at full output.

Greensburg against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Shelbyville, IN20 mi91°F2.5 tons
Columbus, IN25 mi91°F2.5 tons
Connersville, IN29 mi87°F2 tons
Franklin, IN31 mi91°F2.5 tons
Greenfield, IN34 mi91°F2.5 tons
Seymour, IN35 mi89°F2.5 tons

Of 88 Indiana cities here, Greensburg has the 55th highest cooling load. The range runs from Auburn at 24,100 BTU/hr to Jasper at 36,400.

Where Greensburg's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Greensburg, 0.7 miles from the center of Greensburg at 937 ft above sea level. That is close enough that the station's summers are Greensburg's summers.

No other city in this set uses Greensburg, so this sizing is Greensburg's alone.

The sun over Greensburg in late July

At 39.35°N, the noon sun on 21 July stands 71.0° above the horizon over Greensburg and the day runs 14 h 22 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

12,317 people live in Greensburg, the 72nd largest of the 88 Indiana cities sized on this site. Coordinates used: 39.3510, -85.5012.

Greensburg AC sizing questions

What size AC does a 2,000 sq ft house in Greensburg, IN need?

About 2.5 tons, for a cooling load of 29,000 BTU/hr on a 89°F design day. That is one ton per 828 square feet in Greensburg's climate.

Is 20 BTU per square foot right for Greensburg?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Greensburg. For a single room here, plan on 14.5 BTU/hr per square foot.

What does central AC cost to run in Greensburg?

About $265 a year: 1,558 kWh at SEER2 14.3 and 17.04¢ per kWh, over 5 cooling months.