ACSizeCheck

What size AC for Harrison, OH? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Harrison needs

2.5 tons central AC or heat pump, about 30,600 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 37% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 783 square feet in this climate. For a single room, size by the room: 15.3 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cincinnati/Northern Kentucky I (15.9 mi away). Jul is the hottest month, averaging a high of 86°F and a low of 65.9°F, with about 22 days a year at 90°F or more. That gives a design temperature of 91°F against 75°F inside.

What it costs to run

About 1,611 kWh a year at SEER2 14.3, or roughly $303 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Harrison

Of the 30,600 BTU/hr, 11,520 comes through walls, roof and windows on a 91°F afternoon (38%), 13,000 is sun on the house (42%), 2,120 is four people and their appliances, and 4,000 is moisture the coil has to wring out of Harrison's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 26,640 BTU/hr before the moisture allowance.

Other house sizes in Harrison

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,5001.5 tons2 tons
1,500 sq ft23,6002 tons2.5 tons
2,500 sq ft37,7003.5 tons5 tons
3,000 sq ft44,7004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,300 BTU/hr; a 350 sq ft living room needs about 5,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,200 BTU/hr.

Month by month in Harrison

MonthAvg highCooling degree daysAC kWh
Jan39.6°F00
Feb43.7°F00
Mar53.5°F34
Apr65.5°F1622
May74.5°F90125
Jun82.6°F233324
Jul86°F340472
Aug85.2°F309429
Sep78.9°F146202
Oct66.7°F2332
Nov53.8°F11
Dec43.3°F00

Jul alone uses 29% of the year's cooling energy. The unit runs the equivalent of 752 hours a year at full output.

Harrison against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Fairfield, OH14 mi92°F3 tons
Forest Park, OH14 mi92°F3 tons
Hamilton, OH15 mi92°F3 tons
Springdale, OH17 mi92°F3 tons
Cincinnati, OH17 mi91°F2.5 tons
Oxford, OH17 mi92°F3 tons

Of 176 Ohio cities here, Harrison has the 16th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Harrison's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cincinnati/Northern Kentucky I, across the line in Kentucky, 15.9 miles from the center of Harrison at 861 ft above sea level. That is close enough that the station's summers are Harrison's summers.

3 other cities use the same station and get the same climate inputs. The closest to Harrison: Erlanger (18 mi away, 3.9 mi from the station), Florence (20 mi away, 3.8 mi from the station), Independence (24 mi away, 9 mi from the station). Harrison is farther from the station than 3 of them.

The sun over Harrison in late July

At 39.26°N, the noon sun on 21 July stands 71.1° above the horizon over Harrison and the day runs 14 h 22 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

13,526 people live in Harrison, the 133rd largest of the 176 Ohio cities sized on this site. Coordinates used: 39.2566, -84.7862.

Harrison AC sizing questions

What size AC does a 2,000 sq ft house in Harrison, OH need?

About 2.5 tons, for a cooling load of 30,600 BTU/hr on a 91°F design day. That is one ton per 783 square feet in Harrison's climate.

Is 20 BTU per square foot right for Harrison?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Cincinnati/Northern Kentucky I. For a single room here, plan on 15.3 BTU/hr per square foot.

What does central AC cost to run in Harrison?

About $303 a year: 1,611 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.