ACSizeCheck

What size AC for Burlington, WI? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Burlington needs

2 tons central AC or heat pump, about 24,100 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 74% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 996 square feet in this climate. For a single room, size by the room: 12.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Burlington Wwtp (1.9 mi away). Jul is the hottest month, averaging a high of 81°F and a low of 59.3°F, with about 7 days a year at 90°F or more. That gives a design temperature of 85°F against 75°F inside.

What it costs to run

About 652 kWh a year at SEER2 14.3, or roughly $124 at Wisconsin's average residential rate of 19.05¢ per kWh. Cooling runs 3 months of the year here.

What drives the load in Burlington

Of the 24,100 BTU/hr, 7,200 comes through walls, roof and windows on a 85°F afternoon (30%), 13,000 is sun on the house (54%), 2,120 is four people and their appliances, and 1,800 is moisture the coil has to wring out of Burlington's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 22,320 BTU/hr before the moisture allowance.

Other house sizes in Burlington

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,2001.5 tons2 tons
1,500 sq ft18,7001.5 tons2.5 tons
2,500 sq ft29,6002.5 tons5 tons
3,000 sq ft35,0003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,800 BTU/hr; a 350 sq ft living room needs about 4,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,300 BTU/hr.

Month by month in Burlington

MonthAvg highCooling degree daysAC kWh
Jan27.7°F00
Feb31.4°F00
Mar42.7°F01
Apr55.7°F22
May67.1°F2634
Jun76.9°F102133
Jul81°F177232
Aug79.5°F138180
Sep72.9°F4964
Oct60°F56
Nov45.2°F00
Dec32.9°F00

Jul alone uses 36% of the year's cooling energy. The unit runs the equivalent of 387 hours a year at full output.

Burlington against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Salem Lakes, WI12 mi88°F2.5 tons
Elkhorn, WI13 mi87°F2 tons
Muskego, WI15 mi86°F2.5 tons
Antioch, IL17 mi88°F2.5 tons
Fox Lake, IL18 mi86°F2 tons
Franklin, WI20 mi86°F2.5 tons

Of 98 Wisconsin cities here, Burlington has the 84th highest cooling load. The range runs from Two Rivers at 20,200 BTU/hr to La Crosse at 29,800.

Where Burlington's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Burlington Wwtp, 1.9 miles from the center of Burlington at 777 ft above sea level. That is close enough that the station's summers are Burlington's summers.

No other city in this set uses Burlington Wwtp, so this sizing is Burlington's alone.

The sun over Burlington in late July

At 42.68°N, the noon sun on 21 July stands 67.7° above the horizon over Burlington and the day runs 14 h 40 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

10,939 people live in Burlington, the 91st largest of the 98 Wisconsin cities sized on this site. Coordinates used: 42.6752, -88.2719.

Burlington AC sizing questions

What size AC does a 2,000 sq ft house in Burlington, WI need?

About 2 tons, for a cooling load of 24,100 BTU/hr on a 85°F design day. That is one ton per 996 square feet in Burlington's climate.

Is 20 BTU per square foot right for Burlington?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Burlington Wwtp. For a single room here, plan on 12.1 BTU/hr per square foot.

What does central AC cost to run in Burlington?

About $124 a year: 652 kWh at SEER2 14.3 and 19.05¢ per kWh, over 3 cooling months.