What size AC for Fox Lake, IL? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Fox Lake needs

2 tons central AC or heat pump, about 24,900 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 69% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 965 square feet in this climate. For a single room, size by the room: 12.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Chicago Waukegan Regional Airport (16.4 mi away). Jul is the hottest month, averaging a high of 81.3°F and a low of 61.9°F, with about 9 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.

What it costs to run

About 817 kWh a year at SEER2 14.3, or roughly $157 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Fox Lake

Of the 24,900 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (32%), 13,000 is sun on the house (52%), 2,120 is four people and their appliances, and 1,800 is moisture the coil has to wring out of Fox Lake's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.

Other house sizes in Fox Lake

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,6001.5 tons2 tons
1,500 sq ft19,2001.5 tons2.5 tons
2,500 sq ft30,5002.5 tons5 tons
3,000 sq ft36,2003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,400 BTU/hr.

Month by month in Fox Lake

MonthAvg highCooling degree daysAC kWh
Jan30.9°F00
Feb34.1°F00
Mar44.3°F11
Apr55.5°F45
May66.6°F2735
Jun76.6°F113147
Jul81.3°F218284
Aug80°F184241
Sep73.1°F7193
Oct60.9°F811
Nov47.5°F00
Dec35.9°F00

Jul alone uses 35% of the year's cooling energy. The unit runs the equivalent of 470 hours a year at full output.

Fox Lake against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Round Lake Beach, IL6 mi86°F2 tons
Antioch, IL7 mi88°F2.5 tons
Round Lake, IL7 mi86°F2 tons
Salem Lakes, WI8 mi88°F2.5 tons
Lindenhurst, IL8 mi86°F2 tons
McHenry, IL8 mi89°F2.5 tons

Of 225 Illinois cities here, Fox Lake has the lowest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.

Where Fox Lake's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Chicago Waukegan Regional Airport, 16.4 miles from the center of Fox Lake at 710 ft above sea level. That is close enough that the station's summers are Fox Lake's summers.

10 other cities use the same station and get the same climate inputs. The closest to Fox Lake: Round Lake Beach (6 mi away, 11.5 mi from the station), Round Lake (7 mi away, 13.5 mi from the station), Lindenhurst (8 mi away, 8.3 mi from the station), Grayslake (10 mi away, 10.5 mi from the station), Gurnee (13 mi away, 5.4 mi from the station). Fox Lake is farther from the station than 10 of them.

The sun over Fox Lake in late July

At 42.43°N, the noon sun on 21 July stands 68.0° above the horizon over Fox Lake and the day runs 14 h 39 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

10,925 people live in Fox Lake, the 210th largest of the 225 Illinois cities sized on this site. Coordinates used: 42.4282, -88.1839.

Fox Lake AC sizing questions

What size AC does a 2,000 sq ft house in Fox Lake, IL need?

About 2 tons, for a cooling load of 24,900 BTU/hr on a 86°F design day. That is one ton per 965 square feet in Fox Lake's climate.

Is 20 BTU per square foot right for Fox Lake?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Chicago Waukegan Regional Airport. For a single room here, plan on 12.4 BTU/hr per square foot.

What does central AC cost to run in Fox Lake?

About $157 a year: 817 kWh at SEER2 14.3 and 19.23¢ per kWh, over 4 cooling months.