What size AC for York, PA? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in York needs
2.5 tons central AC or heat pump, about 28,000 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 50% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 857 square feet in this climate. For a single room, size by the room: 14 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at York Airport (8.3 mi away). Jul is the hottest month, averaging a high of 85.2°F and a low of 63.1°F, with about 16 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.
What it costs to run
About 1,113 kWh a year at SEER2 14.3, or roughly $235 at Pennsylvania's average residential rate of 21.13¢ per kWh. Cooling runs 4 months of the year here.
What drives the load in York
Of the 28,000 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (39%), 13,000 is sun on the house (46%), 2,120 is four people and their appliances, and 2,100 is moisture the coil has to wring out of York's summer air (8%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.
Other house sizes in York
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 15,100 | 1.5 tons | 2 tons |
| 1,500 sq ft | 21,600 | 2 tons | 2.5 tons |
| 2,500 sq ft | 34,400 | 3 tons | 5 tons |
| 3,000 sq ft | 40,800 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 4,900 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,400 BTU/hr.
Month by month in York
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 39.4°F | 0 | 0 |
| Feb | 42.3°F | 0 | 0 |
| Mar | 51.3°F | 0 | 0 |
| Apr | 63.3°F | 8 | 11 |
| May | 72.6°F | 50 | 65 |
| Jun | 81.1°F | 178 | 233 |
| Jul | 85.2°F | 285 | 372 |
| Aug | 83.5°F | 230 | 300 |
| Sep | 77°F | 89 | 116 |
| Oct | 65.7°F | 12 | 16 |
| Nov | 54.2°F | 0 | 0 |
| Dec | 43.8°F | 0 | 0 |
Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 568 hours a year at full output.
York against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Columbia, PA | 13 mi | 91°F | 2.5 tons |
| Elizabethtown, PA | 15 mi | 92°F | 3 tons |
| Hanover, PA | 17 mi | 90°F | 2.5 tons |
| Mechanicsburg, PA | 22 mi | 92°F | 3 tons |
| Harrisburg, PA | 23 mi | 92°F | 3 tons |
| Lancaster, PA | 23 mi | 91°F | 2.5 tons |
Of 68 Pennsylvania cities here, York has the 28th highest cooling load. The range runs from St. Marys at 21,700 BTU/hr to Philadelphia at 34,300.
Where York's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is York Airport, 8.3 miles from the center of York at 464 ft above sea level. That is close enough that the station's summers are York's summers.
2 other cities use the same station and get the same climate inputs. The closest to York: Hanover (17 mi away, 9.3 mi from the station), Westminster (30 mi away, 24.5 mi from the station). York sits closer to the station than any of them, so its numbers are the best measured of the group.
The sun over York in late July
At 39.96°N, the noon sun on 21 July stands 70.4° above the horizon over York and the day runs 14 h 25 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
45,241 people live in York, the 10th largest of the 68 Pennsylvania cities sized on this site. Coordinates used: 39.9648, -76.7318.
York AC sizing questions
What size AC does a 2,000 sq ft house in York, PA need?
About 2.5 tons, for a cooling load of 28,000 BTU/hr on a 90°F design day. That is one ton per 857 square feet in York's climate.
Is 20 BTU per square foot right for York?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at York Airport. For a single room here, plan on 14 BTU/hr per square foot.
What does central AC cost to run in York?
About $235 a year: 1,113 kWh at SEER2 14.3 and 21.13¢ per kWh, over 4 cooling months.