ACSizeCheck

What size AC for Hanover, PA? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Hanover needs

2.5 tons central AC or heat pump, about 28,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 50% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 857 square feet in this climate. For a single room, size by the room: 14 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at York Airport (9.3 mi away). Jul is the hottest month, averaging a high of 85.2°F and a low of 63.1°F, with about 16 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.

What it costs to run

About 1,113 kWh a year at SEER2 14.3, or roughly $235 at Pennsylvania's average residential rate of 21.13¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Hanover

Of the 28,000 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (39%), 13,000 is sun on the house (46%), 2,120 is four people and their appliances, and 2,100 is moisture the coil has to wring out of Hanover's summer air (8%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.

Other house sizes in Hanover

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft15,1001.5 tons2 tons
1,500 sq ft21,6002 tons2.5 tons
2,500 sq ft34,4003 tons5 tons
3,000 sq ft40,8003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 4,900 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,400 BTU/hr.

Month by month in Hanover

MonthAvg highCooling degree daysAC kWh
Jan39.4°F00
Feb42.3°F00
Mar51.3°F00
Apr63.3°F811
May72.6°F5065
Jun81.1°F178233
Jul85.2°F285372
Aug83.5°F230300
Sep77°F89116
Oct65.7°F1216
Nov54.2°F00
Dec43.8°F00

Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 568 hours a year at full output.

Hanover against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Westminster, MD16 mi90°F2.5 tons
York, PA17 mi90°F2.5 tons
Mechanicsburg, PA28 mi92°F3 tons
Carlisle, PA29 mi90°F2.5 tons
Columbia, PA30 mi91°F2.5 tons
Elizabethtown, PA31 mi92°F3 tons

Of 68 Pennsylvania cities here, Hanover has the 30th highest cooling load. The range runs from St. Marys at 21,700 BTU/hr to Philadelphia at 34,300.

Where Hanover's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is York Airport, 9.3 miles from the center of Hanover at 464 ft above sea level. That is close enough that the station's summers are Hanover's summers.

2 other cities use the same station and get the same climate inputs. The closest to Hanover: Westminster (16 mi away, 24.5 mi from the station), York (17 mi away, 8.3 mi from the station). Hanover is farther from the station than 1 of them.

The sun over Hanover in late July

At 39.81°N, the noon sun on 21 July stands 70.6° above the horizon over Hanover and the day runs 14 h 24 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

16,728 people live in Hanover, the 35th largest of the 68 Pennsylvania cities sized on this site. Coordinates used: 39.8118, -76.9836.

Hanover AC sizing questions

What size AC does a 2,000 sq ft house in Hanover, PA need?

About 2.5 tons, for a cooling load of 28,000 BTU/hr on a 90°F design day. That is one ton per 857 square feet in Hanover's climate.

Is 20 BTU per square foot right for Hanover?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at York Airport. For a single room here, plan on 14 BTU/hr per square foot.

What does central AC cost to run in Hanover?

About $235 a year: 1,113 kWh at SEER2 14.3 and 21.13¢ per kWh, over 4 cooling months.