What size AC for Woodward, OK? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Woodward needs

3.5 tons central AC or heat pump, about 41,300 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.4 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 581 square feet in this climate. For a single room, size by the room: 20.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Woodward 2wsw Mesonet (0.7 mi away). Jul is the hottest month, averaging a high of 94.1°F and a low of 69.7°F, with about 80 days a year at 90°F or more. That gives a design temperature of 101°F against 75°F inside.

What it costs to run

About 2,789 kWh a year at SEER2 14.3, or roughly $385 at Oklahoma's average residential rate of 13.81¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Woodward

Of the 41,300 BTU/hr, 18,720 comes through walls, roof and windows on a 101°F afternoon (45%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 7,400 is moisture the coil has to wring out of Woodward's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,840 BTU/hr before the moisture allowance.

Other house sizes in Woodward

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft21,9002 tons2 tons
1,500 sq ft31,6003 tons2.5 tons
2,500 sq ft51,0004 tons5 tons
3,000 sq ft60,6005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,100 BTU/hr; a 350 sq ft living room needs about 7,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,400 BTU/hr.

Month by month in Woodward

MonthAvg highCooling degree daysAC kWh
Jan49.1°F00
Feb52.7°F22
Mar62.7°F1217
Apr70.7°F3855
May79.6°F152224
Jun88.6°F364537
Jul94.1°F524773
Aug93°F485715
Sep84.7°F248365
Oct72.9°F6393
Nov59.7°F57
Dec49.5°F00

Jul alone uses 28% of the year's cooling energy. The unit runs the equivalent of 966 hours a year at full output.

Woodward against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Elk City, OK72 mi101°F3.5 tons
Weatherford, OK73 mi101°F3.5 tons
Enid, OK85 mi101°F3.5 tons
Liberal, KS95 mi100°F3.5 tons
Dodge City, KS98 mi100°F3.5 tons
El Reno, OK101 mi100°F3.5 tons

Of 45 Oklahoma cities here, Woodward has the 23rd highest cooling load. The range runs from Miami at 35,600 BTU/hr to Ardmore at 44,900.

Where Woodward's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Woodward 2wsw Mesonet, 0.7 miles from the center of Woodward at 2,050 ft above sea level. That is close enough that the station's summers are Woodward's summers.

No other city in this set uses Woodward 2wsw Mesonet, so this sizing is Woodward's alone.

The sun over Woodward in late July

At 36.42°N, the noon sun on 21 July stands 74.0° above the horizon over Woodward and the day runs 14 h 07 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

11,750 people live in Woodward, the 40th largest of the 45 Oklahoma cities sized on this site. Coordinates used: 36.4248, -99.4047.

Woodward AC sizing questions

What size AC does a 2,000 sq ft house in Woodward, OK need?

About 3.5 tons, for a cooling load of 41,300 BTU/hr on a 101°F design day. That is one ton per 581 square feet in Woodward's climate.

Is 20 BTU per square foot right for Woodward?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Woodward 2wsw Mesonet. For a single room here, plan on 20.6 BTU/hr per square foot.

What does central AC cost to run in Woodward?

About $385 a year: 2,789 kWh at SEER2 14.3 and 13.81¢ per kWh, over 6 cooling months.