What size AC for Woodbury, MN? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Woodbury needs
2.5 tons central AC or heat pump, about 27,300 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 54% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 878 square feet in this climate. For a single room, size by the room: 13.7 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at St. Paul Dwtn Airport (6.7 mi away). Jul is the hottest month, averaging a high of 82.6°F and a low of 64°F, with about 12 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.
What it costs to run
About 1,007 kWh a year at SEER2 14.3, or roughly $165 at Minnesota's average residential rate of 16.44¢ per kWh. Cooling runs 4 months of the year here.
What drives the load in Woodbury
Of the 27,300 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (32%), 13,000 is sun on the house (48%), 2,120 is four people and their appliances, and 3,600 is moisture the coil has to wring out of Woodbury's summer air (13%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.
Other house sizes in Woodbury
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 14,900 | 1.5 tons | 2 tons |
| 1,500 sq ft | 21,100 | 2 tons | 2.5 tons |
| 2,500 sq ft | 33,500 | 3 tons | 5 tons |
| 3,000 sq ft | 39,800 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 4,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,200 BTU/hr.
Month by month in Woodbury
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 23.9°F | 0 | 0 |
| Feb | 28.7°F | 0 | 0 |
| Mar | 41.7°F | 0 | 0 |
| Apr | 56.8°F | 3 | 4 |
| May | 68.9°F | 36 | 49 |
| Jun | 78.5°F | 150 | 209 |
| Jul | 82.6°F | 262 | 364 |
| Aug | 80.4°F | 198 | 274 |
| Sep | 72.4°F | 70 | 97 |
| Oct | 58°F | 7 | 9 |
| Nov | 42.1°F | 0 | 0 |
| Dec | 28.6°F | 0 | 0 |
Jul alone uses 36% of the year's cooling energy. The unit runs the equivalent of 527 hours a year at full output.
Woodbury against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Lake Elmo, MN | 6 mi | 87°F | 2.5 tons |
| South St. Paul, MN | 6 mi | 87°F | 2.5 tons |
| Oakdale, MN | 6 mi | 87°F | 2.5 tons |
| Cottage Grove, MN | 6 mi | 87°F | 2.5 tons |
| West St. Paul, MN | 8 mi | 87°F | 2.5 tons |
| North St. Paul, MN | 8 mi | 87°F | 2.5 tons |
Of 103 Minnesota cities here, Woodbury has the 24th highest cooling load. The range runs from Hibbing at 20,200 BTU/hr to Winona at 29,000.
Where Woodbury's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is St. Paul Dwtn Airport, 6.7 miles from the center of Woodbury at 700 ft above sea level. That is close enough that the station's summers are Woodbury's summers.
18 other cities use the same station and get the same climate inputs. The closest to Woodbury: Lake Elmo (6 mi away, 8.1 mi from the station), South St. Paul (6 mi away, 3.1 mi from the station), Oakdale (6 mi away, 5.9 mi from the station), Cottage Grove (6 mi away, 10.7 mi from the station), West St. Paul (8 mi away, 2.5 mi from the station). Woodbury is farther from the station than 7 of them.
The sun over Woodbury in late July
At 44.91°N, the noon sun on 21 July stands 65.5° above the horizon over Woodbury and the day runs 14 h 54 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
80,596 people live in Woodbury, the 7th largest of the 103 Minnesota cities sized on this site. Coordinates used: 44.9063, -92.9237.
Woodbury AC sizing questions
What size AC does a 2,000 sq ft house in Woodbury, MN need?
About 2.5 tons, for a cooling load of 27,300 BTU/hr on a 87°F design day. That is one ton per 878 square feet in Woodbury's climate.
Is 20 BTU per square foot right for Woodbury?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at St. Paul Dwtn Airport. For a single room here, plan on 13.7 BTU/hr per square foot.
What does central AC cost to run in Woodbury?
About $165 a year: 1,007 kWh at SEER2 14.3 and 16.44¢ per kWh, over 4 cooling months.