ACSizeCheck

What size AC for Oakdale, MN? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Oakdale needs

2.5 tons central AC or heat pump, about 27,300 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 54% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 878 square feet in this climate. For a single room, size by the room: 13.7 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at St. Paul Dwtn Airport (5.9 mi away). Jul is the hottest month, averaging a high of 82.6°F and a low of 64°F, with about 12 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 1,007 kWh a year at SEER2 14.3, or roughly $165 at Minnesota's average residential rate of 16.44¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Oakdale

Of the 27,300 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (32%), 13,000 is sun on the house (48%), 2,120 is four people and their appliances, and 3,600 is moisture the coil has to wring out of Oakdale's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Oakdale

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,9001.5 tons2 tons
1,500 sq ft21,1002 tons2.5 tons
2,500 sq ft33,5003 tons5 tons
3,000 sq ft39,8003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 4,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,200 BTU/hr.

Month by month in Oakdale

MonthAvg highCooling degree daysAC kWh
Jan23.9°F00
Feb28.7°F00
Mar41.7°F00
Apr56.8°F34
May68.9°F3649
Jun78.5°F150209
Jul82.6°F262364
Aug80.4°F198274
Sep72.4°F7097
Oct58°F79
Nov42.1°F00
Dec28.6°F00

Jul alone uses 36% of the year's cooling energy. The unit runs the equivalent of 527 hours a year at full output.

Oakdale against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
North St. Paul, MN3 mi87°F2.5 tons
Lake Elmo, MN3 mi87°F2.5 tons
Maplewood, MN4 mi87°F2.5 tons
White Bear Lake, MN6 mi87°F2.5 tons
Woodbury, MN6 mi87°F2.5 tons
Little Canada, MN6 mi87°F2.5 tons

Of 103 Minnesota cities here, Oakdale has the 29th highest cooling load. The range runs from Hibbing at 20,200 BTU/hr to Winona at 29,000.

Where Oakdale's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is St. Paul Dwtn Airport, 5.9 miles from the center of Oakdale at 700 ft above sea level. That is close enough that the station's summers are Oakdale's summers.

18 other cities use the same station and get the same climate inputs. The closest to Oakdale: North St. Paul (3 mi away, 6.2 mi from the station), Lake Elmo (3 mi away, 8.1 mi from the station), Maplewood (4 mi away, 6.1 mi from the station), White Bear Lake (6 mi away, 9.4 mi from the station), Woodbury (6 mi away, 6.7 mi from the station). Oakdale is farther from the station than 3 of them.

The sun over Oakdale in late July

At 44.99°N, the noon sun on 21 July stands 65.4° above the horizon over Oakdale and the day runs 14 h 55 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

30,441 people live in Oakdale, the 34th largest of the 103 Minnesota cities sized on this site. Coordinates used: 44.9875, -92.9636.

Oakdale AC sizing questions

What size AC does a 2,000 sq ft house in Oakdale, MN need?

About 2.5 tons, for a cooling load of 27,300 BTU/hr on a 87°F design day. That is one ton per 878 square feet in Oakdale's climate.

Is 20 BTU per square foot right for Oakdale?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at St. Paul Dwtn Airport. For a single room here, plan on 13.7 BTU/hr per square foot.

What does central AC cost to run in Oakdale?

About $165 a year: 1,007 kWh at SEER2 14.3 and 16.44¢ per kWh, over 4 cooling months.