What size AC for Waynesboro, PA? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Waynesboro needs

3 tons central AC or heat pump, about 31,500 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 33% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 763 square feet in this climate. For a single room, size by the room: 15.7 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Hagerstown Regional Airport (8.5 mi away). Jul is the hottest month, averaging a high of 87.3°F and a low of 67.9°F, with about 24 days a year at 90°F or more. That gives a design temperature of 92°F against 75°F inside.

What it costs to run

About 1,735 kWh a year at SEER2 14.3, or roughly $367 at Pennsylvania's average residential rate of 21.13¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Waynesboro

Of the 31,500 BTU/hr, 12,240 comes through walls, roof and windows on a 92°F afternoon (39%), 13,000 is sun on the house (41%), 2,120 is four people and their appliances, and 4,100 is moisture the coil has to wring out of Waynesboro's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 27,360 BTU/hr before the moisture allowance.

Other house sizes in Waynesboro

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft17,0001.5 tons2 tons
1,500 sq ft24,2002 tons2.5 tons
2,500 sq ft38,7003.5 tons5 tons
3,000 sq ft46,0004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,400 BTU/hr; a 350 sq ft living room needs about 5,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,400 BTU/hr.

Month by month in Waynesboro

MonthAvg highCooling degree daysAC kWh
Jan40.5°F00
Feb43.6°F00
Mar52.8°F12
Apr64.9°F2028
May74.4°F93129
Jun82.6°F255354
Jul87.3°F391543
Aug84.9°F321446
Sep77.8°F145201
Oct66°F2230
Nov54.4°F01
Dec44°F00

Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 788 hours a year at full output.

Waynesboro against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Hagerstown, MD11 mi92°F3 tons
Chambersburg, PA13 mi90°F2.5 tons
Frederick, MD24 mi94°F3 tons
Martinsburg, WV29 mi92°F3 tons
Hanover, PA32 mi90°F2.5 tons
Westminster, MD33 mi90°F2.5 tons

Of 68 Pennsylvania cities here, Waynesboro has the 8th highest cooling load. The range runs from St. Marys at 21,700 BTU/hr to Philadelphia at 34,300.

Where Waynesboro's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Hagerstown Regional Airport, across the line in Maryland, 8.5 miles from the center of Waynesboro at 687 ft above sea level. That is close enough that the station's summers are Waynesboro's summers.

1 other city uses the same station and get the same climate inputs. The closest to Waynesboro: Hagerstown (11 mi away, 4.7 mi from the station). Waynesboro is farther from the station than 1 of them.

The sun over Waynesboro in late July

At 39.75°N, the noon sun on 21 July stands 70.6° above the horizon over Waynesboro and the day runs 14 h 24 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

11,101 people live in Waynesboro, the 61st largest of the 68 Pennsylvania cities sized on this site. Coordinates used: 39.7524, -77.5823.

Waynesboro AC sizing questions

What size AC does a 2,000 sq ft house in Waynesboro, PA need?

About 3 tons, for a cooling load of 31,500 BTU/hr on a 92°F design day. That is one ton per 763 square feet in Waynesboro's climate.

Is 20 BTU per square foot right for Waynesboro?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Hagerstown Regional Airport. For a single room here, plan on 15.7 BTU/hr per square foot.

What does central AC cost to run in Waynesboro?

About $367 a year: 1,735 kWh at SEER2 14.3 and 21.13¢ per kWh, over 5 cooling months.