What size AC for Wasilla, AK? 1.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Wasilla needs
1.5 tons central AC or heat pump, about 15,700 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 167% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 1.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,526 square feet in this climate. For a single room, size by the room: 7.9 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Palmer Airport (12.2 mi away). Jul is the hottest month, averaging a high of 67.6°F and a low of 50.7°F, with about 0 days a year at 90°F or more. That gives a design temperature of 72°F against 75°F inside.
What it costs to run
About 6 kWh a year at SEER2 14.3, or roughly $2 at Alaska's average residential rate of 27.32¢ per kWh. Cooling runs 0 months of the year here.
What drives the load in Wasilla
Of the 15,700 BTU/hr, 0 comes through walls, roof and windows on a 72°F afternoon (0%), 13,000 is sun on the house (83%), 2,120 is four people and their appliances, and 600 is moisture the coil has to wring out of Wasilla's summer air (4%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 15,120 BTU/hr before the moisture allowance.
Other house sizes in Wasilla
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 9,000 | 1.5 tons | 2 tons |
| 1,500 sq ft | 12,300 | 1.5 tons | 2.5 tons |
| 2,500 sq ft | 19,100 | 1.5 tons | 5 tons |
| 3,000 sq ft | 22,500 | 2 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,200 BTU/hr; a 350 sq ft living room needs about 2,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 4,700 BTU/hr.
Month by month in Wasilla
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 22.4°F | 0 | 0 |
| Feb | 28.3°F | 0 | 0 |
| Mar | 33.9°F | 0 | 0 |
| Apr | 47.8°F | 0 | 0 |
| May | 59.1°F | 0 | 0 |
| Jun | 65.7°F | 2 | 2 |
| Jul | 67.6°F | 3 | 4 |
| Aug | 64.6°F | 1 | 1 |
| Sep | 55.8°F | 0 | 0 |
| Oct | 42.3°F | 0 | 0 |
| Nov | 28.9°F | 0 | 0 |
| Dec | 25.1°F | 0 | 0 |
Jul alone uses 67% of the year's cooling energy. The unit runs the equivalent of 6 hours a year at full output.
Wasilla against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Anchorage, AK | 29 mi | 72°F | 1.5 tons |
| Fairbanks, AK | 232 mi | 77°F | 1.5 tons |
| Juneau, AK | 566 mi | 68°F | 1.5 tons |
| Lynden, WA | 1358 mi | 77°F | 1.5 tons |
| Ferndale, WA | 1359 mi | 77°F | 1.5 tons |
| Bellingham, WA | 1368 mi | 77°F | 1.5 tons |
Of 4 Alaska cities here, Wasilla has the lowest cooling load. The range runs from Wasilla at 15,700 BTU/hr to Fairbanks at 17,200.
Where Wasilla's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Palmer Airport, 12.2 miles from the center of Wasilla at 233 ft above sea level. That is close enough that the station's summers are Wasilla's summers.
No other city in this set uses Palmer Airport, so this sizing is Wasilla's alone.
The sun over Wasilla in late July
At 61.58°N, the noon sun on 21 July stands 48.8° above the horizon over Wasilla and the day runs 17 h 47 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
10,318 people live in Wasilla, the 4th largest of the 4 Alaska cities sized on this site. Coordinates used: 61.5811, -149.4608.
Wasilla AC sizing questions
What size AC does a 2,000 sq ft house in Wasilla, AK need?
About 1.5 tons, for a cooling load of 15,700 BTU/hr on a 72°F design day. That is one ton per 1,526 square feet in Wasilla's climate.
Is 20 BTU per square foot right for Wasilla?
The chart gives 3.5 tons for 2,000 sq ft, against 1.5 tons sized from NOAA's 1991 to 2020 normals at Palmer Airport. For a single room here, plan on 7.9 BTU/hr per square foot.
What does central AC cost to run in Wasilla?
About $2 a year: 6 kWh at SEER2 14.3 and 27.32¢ per kWh, over 0 cooling months.