ACSizeCheck

What size AC for Lynden, WA? 1.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Lynden needs

1.5 tons central AC or heat pump, about 17,200 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 144% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 1.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,394 square feet in this climate. For a single room, size by the room: 8.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Bellingham International Airport (11.1 mi away). Aug is the hottest month, averaging a high of 73.1°F and a low of 54.7°F, with about 0 days a year at 90°F or more. That gives a design temperature of 77°F against 75°F inside.

What it costs to run

About 95 kWh a year at SEER2 14.3, or roughly $14 at Washington's average residential rate of 14.42¢ per kWh. Cooling runs 0 months of the year here.

What drives the load in Lynden

Of the 17,200 BTU/hr, 1,440 comes through walls, roof and windows on a 77°F afternoon (8%), 13,000 is sun on the house (76%), 2,120 is four people and their appliances, and 700 is moisture the coil has to wring out of Lynden's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 16,560 BTU/hr before the moisture allowance.

Other house sizes in Lynden

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft9,7001.5 tons2 tons
1,500 sq ft13,5001.5 tons2.5 tons
2,500 sq ft21,0002 tons5 tons
3,000 sq ft24,7002 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,300 BTU/hr; a 350 sq ft living room needs about 3,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 5,200 BTU/hr.

Month by month in Lynden

MonthAvg highCooling degree daysAC kWh
Jan46.3°F00
Feb48.9°F00
Mar52.8°F00
Apr57.7°F00
May63.9°F11
Jun67.8°F810
Jul72.7°F3139
Aug73.1°F3139
Sep68.1°F46
Oct58.9°F00
Nov51°F00
Dec45.5°F00

Jul alone uses 41% of the year's cooling energy. The unit runs the equivalent of 78 hours a year at full output.

Lynden against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Ferndale, WA9 mi77°F1.5 tons
Bellingham, WA14 mi77°F1.5 tons
Sedro-Woolley, WA32 mi79°F1.5 tons
Anacortes, WA33 mi74°F1.5 tons
Burlington, WA34 mi74°F1.5 tons
Mount Vernon, WA37 mi74°F1.5 tons

Of 91 Washington cities here, Lynden has the 82nd highest cooling load. The range runs from Burlington at 15,700 BTU/hr to Kennewick at 32,900.

Where Lynden's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Bellingham International Airport, 11.1 miles from the center of Lynden at 150 ft above sea level. That is close enough that the station's summers are Lynden's summers.

2 other cities use the same station and get the same climate inputs. The closest to Lynden: Ferndale (9 mi away, 4.4 mi from the station), Bellingham (14 mi away, 4.5 mi from the station). Lynden is farther from the station than 2 of them.

The sun over Lynden in late July

At 48.95°N, the noon sun on 21 July stands 61.5° above the horizon over Lynden and the day runs 15 h 22 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

16,783 people live in Lynden, the 66th largest of the 91 Washington cities sized on this site. Coordinates used: 48.9499, -122.4548.

Lynden AC sizing questions

What size AC does a 2,000 sq ft house in Lynden, WA need?

About 1.5 tons, for a cooling load of 17,200 BTU/hr on a 77°F design day. That is one ton per 1,394 square feet in Lynden's climate.

Is 20 BTU per square foot right for Lynden?

The chart gives 3.5 tons for 2,000 sq ft, against 1.5 tons sized from NOAA's 1991 to 2020 normals at Bellingham International Airport. For a single room here, plan on 8.6 BTU/hr per square foot.

What does central AC cost to run in Lynden?

About $14 a year: 95 kWh at SEER2 14.3 and 14.42¢ per kWh, over 0 cooling months.