What size AC for Upper Arlington, OH? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Upper Arlington needs

2.5 tons central AC or heat pump, about 29,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 45% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 828 square feet in this climate. For a single room, size by the room: 14.5 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Columbus Ohio State University Airport (3.5 mi away). Jul is the hottest month, averaging a high of 84.3°F and a low of 64°F, with about 17 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.

What it costs to run

About 1,277 kWh a year at SEER2 14.3, or roughly $240 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Upper Arlington

Of the 29,000 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (35%), 13,000 is sun on the house (45%), 2,120 is four people and their appliances, and 3,800 is moisture the coil has to wring out of Upper Arlington's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.

Other house sizes in Upper Arlington

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft15,7001.5 tons2 tons
1,500 sq ft22,3002 tons2.5 tons
2,500 sq ft35,6003 tons5 tons
3,000 sq ft42,3004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,700 BTU/hr.

Month by month in Upper Arlington

MonthAvg highCooling degree daysAC kWh
Jan36.3°F00
Feb39.8°F00
Mar50.2°F22
Apr63.3°F1013
May73.3°F6996
Jun81.3°F193268
Jul84.3°F285396
Aug83.2°F245340
Sep77°F100139
Oct64.7°F1520
Nov51.4°F00
Dec40.4°F00

Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 630 hours a year at full output.

Upper Arlington against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Hilliard, OH5 mi89°F2.5 tons
Columbus, OH5 mi90°F2.5 tons
Worthington, OH5 mi89°F2.5 tons
Dublin, OH7 mi89°F2.5 tons
Bexley, OH8 mi90°F2.5 tons
Powell, OH10 mi89°F2.5 tons

Of 176 Ohio cities here, Upper Arlington has the 72nd highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Upper Arlington's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Columbus Ohio State University Airport, 3.5 miles from the center of Upper Arlington at 902 ft above sea level. That is close enough that the station's summers are Upper Arlington's summers.

7 other cities use the same station and get the same climate inputs. The closest to Upper Arlington: Hilliard (5 mi away, 5.2 mi from the station), Worthington (5 mi away, 3.3 mi from the station), Dublin (7 mi away, 4.3 mi from the station), Powell (10 mi away, 6.2 mi from the station), Westerville (11 mi away, 9.3 mi from the station). Upper Arlington is farther from the station than 1 of them.

The sun over Upper Arlington in late July

At 40.03°N, the noon sun on 21 July stands 70.4° above the horizon over Upper Arlington and the day runs 14 h 26 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

36,140 people live in Upper Arlington, the 37th largest of the 176 Ohio cities sized on this site. Coordinates used: 40.0276, -83.0707.

Upper Arlington AC sizing questions

What size AC does a 2,000 sq ft house in Upper Arlington, OH need?

About 2.5 tons, for a cooling load of 29,000 BTU/hr on a 89°F design day. That is one ton per 828 square feet in Upper Arlington's climate.

Is 20 BTU per square foot right for Upper Arlington?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Columbus Ohio State University Airport. For a single room here, plan on 14.5 BTU/hr per square foot.

What does central AC cost to run in Upper Arlington?

About $240 a year: 1,277 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.