ACSizeCheck

What size AC for Stephenville, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Stephenville needs

4 tons central AC or heat pump, about 44,800 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.7 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 536 square feet in this climate. For a single room, size by the room: 22.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Stephenville Clark Field (2.5 mi away). Aug is the hottest month, averaging a high of 97.6°F and a low of 69.6°F, with about 98 days a year at 90°F or more. That gives a design temperature of 105°F against 75°F inside.

What it costs to run

About 3,688 kWh a year at SEER2 14.3, or roughly $591 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Stephenville

Of the 44,800 BTU/hr, 21,600 comes through walls, roof and windows on a 105°F afternoon (48%), 13,000 is sun on the house (29%), 2,120 is four people and their appliances, and 8,100 is moisture the coil has to wring out of Stephenville's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,720 BTU/hr before the moisture allowance.

Other house sizes in Stephenville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft23,7002 tons2 tons
1,500 sq ft34,2003 tons2.5 tons
2,500 sq ft55,4005 tons5 tons
3,000 sq ft65,9005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,400 BTU/hr; a 350 sq ft living room needs about 7,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 13,400 BTU/hr.

Month by month in Stephenville

MonthAvg highCooling degree daysAC kWh
Jan59.1°F22
Feb63.1°F57
Mar70.4°F2638
Apr78.6°F90133
May85.6°F260383
Jun93.1°F461679
Jul97.3°F587866
Aug97.6°F577850
Sep90.2°F348513
Oct80.5°F124183
Nov68.8°F2030
Dec60.5°F23

Jul alone uses 23% of the year's cooling energy. The unit runs the equivalent of 1,177 hours a year at full output.

Stephenville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Granbury, TX30 mi104°F4 tons
Mineral Wells, TX43 mi104°F4 tons
Weatherford, TX46 mi102°F4 tons
Cleburne, TX48 mi103°F4 tons
Benbrook, TX55 mi105°F4 tons
Crowley, TX56 mi105°F4 tons

Of 252 Texas cities here, Stephenville has the 175th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Stephenville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Stephenville Clark Field, 2.5 miles from the center of Stephenville at 1,321 ft above sea level. That is close enough that the station's summers are Stephenville's summers.

No other city in this set uses Stephenville Clark Field, so this sizing is Stephenville's alone.

The sun over Stephenville in late July

At 32.21°N, the noon sun on 21 July stands 78.2° above the horizon over Stephenville and the day runs 13 h 48 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

22,147 people live in Stephenville, the 144th largest of the 252 Texas cities sized on this site. Coordinates used: 32.2145, -98.2199.

Stephenville AC sizing questions

What size AC does a 2,000 sq ft house in Stephenville, TX need?

About 4 tons, for a cooling load of 44,800 BTU/hr on a 105°F design day. That is one ton per 536 square feet in Stephenville's climate.

Is 20 BTU per square foot right for Stephenville?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Stephenville Clark Field. For a single room here, plan on 22.4 BTU/hr per square foot.

What does central AC cost to run in Stephenville?

About $591 a year: 3,688 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.