What size AC for Weatherford, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Weatherford needs
4 tons central AC or heat pump, about 44,900 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.7 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 534 square feet in this climate. For a single room, size by the room: 22.5 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Weatherford (0.5 mi away). Aug is the hottest month, averaging a high of 94.7°F and a low of 72°F, with about 90 days a year at 90°F or more. That gives a design temperature of 102°F against 75°F inside.
What it costs to run
About 3,752 kWh a year at SEER2 14.3, or roughly $601 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Weatherford
Of the 44,900 BTU/hr, 19,440 comes through walls, roof and windows on a 102°F afternoon (43%), 13,000 is sun on the house (29%), 2,120 is four people and their appliances, and 10,400 is moisture the coil has to wring out of Weatherford's summer air (23%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 34,560 BTU/hr before the moisture allowance.
Other house sizes in Weatherford
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 23,800 | 2 tons | 2 tons |
| 1,500 sq ft | 34,400 | 3 tons | 2.5 tons |
| 2,500 sq ft | 55,500 | 5 tons | 5 tons |
| 3,000 sq ft | 66,000 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,400 BTU/hr; a 350 sq ft living room needs about 7,900 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 13,500 BTU/hr.
Month by month in Weatherford
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 56.2°F | 1 | 2 |
| Feb | 60°F | 4 | 6 |
| Mar | 67.9°F | 21 | 34 |
| Apr | 75.8°F | 77 | 120 |
| May | 82.4°F | 233 | 366 |
| Jun | 90°F | 441 | 693 |
| Jul | 94.6°F | 581 | 913 |
| Aug | 94.7°F | 569 | 893 |
| Sep | 87.7°F | 334 | 525 |
| Oct | 77.8°F | 109 | 171 |
| Nov | 66.2°F | 16 | 26 |
| Dec | 57.9°F | 2 | 3 |
Jul alone uses 24% of the year's cooling energy. The unit runs the equivalent of 1,194 hours a year at full output.
Weatherford against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Azle, TX | 16 mi | 105°F | 4 tons |
| White Settlement, TX | 18 mi | 105°F | 4 tons |
| Benbrook, TX | 18 mi | 105°F | 4 tons |
| Mineral Wells, TX | 19 mi | 104°F | 4 tons |
| Granbury, TX | 22 mi | 104°F | 4 tons |
| Fort Worth, TX | 24 mi | 105°F | 4 tons |
Of 252 Texas cities here, Weatherford has the 167th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where Weatherford's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Weatherford, 0.5 miles from the center of Weatherford at 955 ft above sea level. That is close enough that the station's summers are Weatherford's summers.
No other city in this set uses Weatherford, so this sizing is Weatherford's alone.
The sun over Weatherford in late July
At 32.76°N, the noon sun on 21 July stands 77.6° above the horizon over Weatherford and the day runs 13 h 51 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
39,397 people live in Weatherford, the 94th largest of the 252 Texas cities sized on this site. Coordinates used: 32.7554, -97.7657.
Weatherford AC sizing questions
What size AC does a 2,000 sq ft house in Weatherford, TX need?
About 4 tons, for a cooling load of 44,900 BTU/hr on a 102°F design day. That is one ton per 534 square feet in Weatherford's climate.
Is 20 BTU per square foot right for Weatherford?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Weatherford. For a single room here, plan on 22.5 BTU/hr per square foot.
What does central AC cost to run in Weatherford?
About $601 a year: 3,752 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.