What size AC for Spanish Fort, AL? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Spanish Fort needs
3 tons central AC or heat pump, about 35,100 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 20% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 683 square feet in this climate. For a single room, size by the room: 17.6 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Fairhope 3 Ne (12.1 mi away). Aug is the hottest month, averaging a high of 88.7°F and a low of 71°F, with about 47 days a year at 90°F or more. That gives a design temperature of 94°F against 75°F inside.
What it costs to run
About 3,232 kWh a year at SEER2 14.3, or roughly $534 at Alabama's average residential rate of 16.51¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Spanish Fort
Of the 35,100 BTU/hr, 13,680 comes through walls, roof and windows on a 94°F afternoon (39%), 13,000 is sun on the house (37%), 2,120 is four people and their appliances, and 6,300 is moisture the coil has to wring out of Spanish Fort's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 28,800 BTU/hr before the moisture allowance.
Other house sizes in Spanish Fort
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 18,900 | 1.5 tons | 2 tons |
| 1,500 sq ft | 27,000 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 43,300 | 4 tons | 5 tons |
| 3,000 sq ft | 51,400 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,600 BTU/hr; a 350 sq ft living room needs about 6,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,600 BTU/hr.
Month by month in Spanish Fort
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 60.9°F | 8 | 12 |
| Feb | 65°F | 16 | 24 |
| Mar | 70.3°F | 25 | 37 |
| Apr | 76.1°F | 71 | 104 |
| May | 83.1°F | 227 | 334 |
| Jun | 86.8°F | 394 | 581 |
| Jul | 88.6°F | 473 | 697 |
| Aug | 88.7°F | 460 | 679 |
| Sep | 86.2°F | 342 | 503 |
| Oct | 78.6°F | 137 | 201 |
| Nov | 69.6°F | 27 | 40 |
| Dec | 63.5°F | 13 | 20 |
Jul alone uses 22% of the year's cooling energy. The unit runs the equivalent of 1,316 hours a year at full output.
Spanish Fort against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Daphne, AL | 7 mi | 94°F | 3 tons |
| Fairhope, AL | 14 mi | 94°F | 3 tons |
| Mobile, AL | 15 mi | 98°F | 3.5 tons |
| Prichard, AL | 16 mi | 97°F | 3.5 tons |
| Saraland, AL | 17 mi | 97°F | 3.5 tons |
| Foley, AL | 25 mi | 94°F | 3 tons |
Of 66 Alabama cities here, Spanish Fort has the 61st highest cooling load. The range runs from Boaz at 30,600 BTU/hr to Montgomery at 44,000.
Where Spanish Fort's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Fairhope 3 Ne, 12.1 miles from the center of Spanish Fort at 95 ft above sea level. That is close enough that the station's summers are Spanish Fort's summers.
4 other cities use the same station and get the same climate inputs. The closest to Spanish Fort: Daphne (7 mi away, 5.2 mi from the station), Fairhope (14 mi away, 1.9 mi from the station), Foley (25 mi away, 16.2 mi from the station), Gulf Shores (32 mi away, 21.4 mi from the station). Spanish Fort is farther from the station than 2 of them.
The sun over Spanish Fort in late July
At 30.72°N, the noon sun on 21 July stands 79.7° above the horizon over Spanish Fort and the day runs 13 h 42 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
11,118 people live in Spanish Fort, the 61st largest of the 66 Alabama cities sized on this site. Coordinates used: 30.7230, -87.8659.
Spanish Fort AC sizing questions
What size AC does a 2,000 sq ft house in Spanish Fort, AL need?
About 3 tons, for a cooling load of 35,100 BTU/hr on a 94°F design day. That is one ton per 683 square feet in Spanish Fort's climate.
Is 20 BTU per square foot right for Spanish Fort?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Fairhope 3 Ne. For a single room here, plan on 17.6 BTU/hr per square foot.
What does central AC cost to run in Spanish Fort?
About $534 a year: 3,232 kWh at SEER2 14.3 and 16.51¢ per kWh, over 7 cooling months.