ACSizeCheck

What size AC for Foley, AL? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Foley needs

3 tons central AC or heat pump, about 35,100 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 20% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 683 square feet in this climate. For a single room, size by the room: 17.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Fairhope 3 Ne (16.2 mi away). Aug is the hottest month, averaging a high of 88.7°F and a low of 71°F, with about 47 days a year at 90°F or more. That gives a design temperature of 94°F against 75°F inside.

What it costs to run

About 3,232 kWh a year at SEER2 14.3, or roughly $534 at Alabama's average residential rate of 16.51¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Foley

Of the 35,100 BTU/hr, 13,680 comes through walls, roof and windows on a 94°F afternoon (39%), 13,000 is sun on the house (37%), 2,120 is four people and their appliances, and 6,300 is moisture the coil has to wring out of Foley's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 28,800 BTU/hr before the moisture allowance.

Other house sizes in Foley

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft18,9001.5 tons2 tons
1,500 sq ft27,0002.5 tons2.5 tons
2,500 sq ft43,3004 tons5 tons
3,000 sq ft51,4004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,600 BTU/hr; a 350 sq ft living room needs about 6,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,600 BTU/hr.

Month by month in Foley

MonthAvg highCooling degree daysAC kWh
Jan60.9°F812
Feb65°F1624
Mar70.3°F2537
Apr76.1°F71104
May83.1°F227334
Jun86.8°F394581
Jul88.6°F473697
Aug88.7°F460679
Sep86.2°F342503
Oct78.6°F137201
Nov69.6°F2740
Dec63.5°F1320

Jul alone uses 22% of the year's cooling energy. The unit runs the equivalent of 1,316 hours a year at full output.

Foley against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Gulf Shores, AL9 mi94°F3 tons
Fairhope, AL15 mi94°F3 tons
Daphne, AL20 mi94°F3 tons
Spanish Fort, AL25 mi94°F3 tons
Pensacola, FL29 mi98°F3.5 tons
Mobile, AL32 mi98°F3.5 tons

Of 66 Alabama cities here, Foley has the 57th highest cooling load. The range runs from Boaz at 30,600 BTU/hr to Montgomery at 44,000.

Where Foley's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Fairhope 3 Ne, 16.2 miles from the center of Foley at 95 ft above sea level. That is close enough that the station's summers are Foley's summers.

4 other cities use the same station and get the same climate inputs. The closest to Foley: Gulf Shores (9 mi away, 21.4 mi from the station), Fairhope (15 mi away, 1.9 mi from the station), Daphne (20 mi away, 5.2 mi from the station), Spanish Fort (25 mi away, 12.1 mi from the station). Foley is farther from the station than 3 of them.

The sun over Foley in late July

At 30.40°N, the noon sun on 21 July stands 80.0° above the horizon over Foley and the day runs 13 h 41 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

28,043 people live in Foley, the 22nd largest of the 66 Alabama cities sized on this site. Coordinates used: 30.3971, -87.6685.

Foley AC sizing questions

What size AC does a 2,000 sq ft house in Foley, AL need?

About 3 tons, for a cooling load of 35,100 BTU/hr on a 94°F design day. That is one ton per 683 square feet in Foley's climate.

Is 20 BTU per square foot right for Foley?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Fairhope 3 Ne. For a single room here, plan on 17.6 BTU/hr per square foot.

What does central AC cost to run in Foley?

About $534 a year: 3,232 kWh at SEER2 14.3 and 16.51¢ per kWh, over 7 cooling months.