What size AC for Sherman, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Sherman needs
4 tons central AC or heat pump, about 42,100 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.5 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 570 square feet in this climate. For a single room, size by the room: 21.1 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Sherman (5.2 mi away). Aug is the hottest month, averaging a high of 92.7°F and a low of 73°F, with about 73 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.
What it costs to run
About 3,552 kWh a year at SEER2 14.3, or roughly $569 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Sherman
Of the 42,100 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (41%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 9,700 is moisture the coil has to wring out of Sherman's summer air (23%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.
Other house sizes in Sherman
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 22,400 | 2 tons | 2 tons |
| 1,500 sq ft | 32,300 | 3 tons | 2.5 tons |
| 2,500 sq ft | 52,000 | 4 tons | 5 tons |
| 3,000 sq ft | 61,800 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,700 BTU/hr.
Month by month in Sherman
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 52.6°F | 1 | 1 |
| Feb | 57.1°F | 2 | 4 |
| Mar | 65.2°F | 17 | 26 |
| Apr | 72.6°F | 58 | 92 |
| May | 80°F | 203 | 319 |
| Jun | 88.1°F | 419 | 658 |
| Jul | 92.5°F | 558 | 876 |
| Aug | 92.7°F | 553 | 869 |
| Sep | 85.4°F | 330 | 518 |
| Oct | 75.3°F | 106 | 167 |
| Nov | 63.3°F | 12 | 19 |
| Dec | 54.2°F | 2 | 3 |
Jul alone uses 25% of the year's cooling energy. The unit runs the equivalent of 1,206 hours a year at full output.
Sherman against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Denison, TX | 10 mi | 99°F | 4 tons |
| Anna, TX | 20 mi | 103°F | 4 tons |
| Celina, TX | 23 mi | 103°F | 4 tons |
| Melissa, TX | 24 mi | 103°F | 4 tons |
| Bonham, TX | 25 mi | 100°F | 4 tons |
| Durant, OK | 29 mi | 102°F | 4 tons |
Of 252 Texas cities here, Sherman has the 230th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where Sherman's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Sherman, 5.2 miles from the center of Sherman at 760 ft above sea level. That is close enough that the station's summers are Sherman's summers.
1 other city uses the same station and get the same climate inputs. The closest to Sherman: Denison (10 mi away, 5.6 mi from the station). Sherman sits closer to the station than any of them, so its numbers are the best measured of the group.
The sun over Sherman in late July
At 33.63°N, the noon sun on 21 July stands 76.8° above the horizon over Sherman and the day runs 13 h 55 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
50,229 people live in Sherman, the 75th largest of the 252 Texas cities sized on this site. Coordinates used: 33.6286, -96.6267.
Sherman AC sizing questions
What size AC does a 2,000 sq ft house in Sherman, TX need?
About 4 tons, for a cooling load of 42,100 BTU/hr on a 99°F design day. That is one ton per 570 square feet in Sherman's climate.
Is 20 BTU per square foot right for Sherman?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Sherman. For a single room here, plan on 21.1 BTU/hr per square foot.
What does central AC cost to run in Sherman?
About $569 a year: 3,552 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.