ACSizeCheck

What size AC for Bonham, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Bonham needs

4 tons central AC or heat pump, about 43,100 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.6 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 557 square feet in this climate. For a single room, size by the room: 21.5 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Bonham 3nne (3.9 mi away). Aug is the hottest month, averaging a high of 93.8°F and a low of 72.4°F, with about 78 days a year at 90°F or more. That gives a design temperature of 100°F against 75°F inside.

What it costs to run

About 3,628 kWh a year at SEER2 14.3, or roughly $582 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Bonham

Of the 43,100 BTU/hr, 18,000 comes through walls, roof and windows on a 100°F afternoon (42%), 13,000 is sun on the house (30%), 2,120 is four people and their appliances, and 9,900 is moisture the coil has to wring out of Bonham's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,120 BTU/hr before the moisture allowance.

Other house sizes in Bonham

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,9002 tons2 tons
1,500 sq ft33,0003 tons2.5 tons
2,500 sq ft53,1005 tons5 tons
3,000 sq ft63,2005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,900 BTU/hr.

Month by month in Bonham

MonthAvg highCooling degree daysAC kWh
Jan52.9°F11
Feb57.3°F24
Mar65.2°F1524
Apr73.4°F5892
May80.6°F211331
Jun88.9°F428672
Jul93.6°F574901
Aug93.8°F561881
Sep86.9°F335527
Oct76.5°F107168
Nov64.5°F1624
Dec54.9°F23

Jul alone uses 25% of the year's cooling energy. The unit runs the equivalent of 1,205 hours a year at full output.

Bonham against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Sherman, TX25 mi99°F4 tons
Denison, TX26 mi99°F4 tons
Anna, TX27 mi103°F4 tons
Melissa, TX30 mi103°F4 tons
Durant, OK30 mi102°F4 tons
Greenville, TX33 mi106°F4 tons

Of 252 Texas cities here, Bonham has the 214th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Bonham's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Bonham 3nne, 3.9 miles from the center of Bonham at 592 ft above sea level. That is close enough that the station's summers are Bonham's summers.

No other city in this set uses Bonham 3nne, so this sizing is Bonham's alone.

The sun over Bonham in late July

At 33.59°N, the noon sun on 21 July stands 76.8° above the horizon over Bonham and the day runs 13 h 54 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

11,115 people live in Bonham, the 230th largest of the 252 Texas cities sized on this site. Coordinates used: 33.5880, -96.1901.

Bonham AC sizing questions

What size AC does a 2,000 sq ft house in Bonham, TX need?

About 4 tons, for a cooling load of 43,100 BTU/hr on a 100°F design day. That is one ton per 557 square feet in Bonham's climate.

Is 20 BTU per square foot right for Bonham?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Bonham 3nne. For a single room here, plan on 21.5 BTU/hr per square foot.

What does central AC cost to run in Bonham?

About $582 a year: 3,628 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.