ACSizeCheck

What size AC for Roseville, MI? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Roseville needs

2.5 tons central AC or heat pump, about 28,200 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 49% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 853 square feet in this climate. For a single room, size by the room: 14.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Detroit City Airport (7.9 mi away). Jul is the hottest month, averaging a high of 83.5°F and a low of 64.9°F, with about 13 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.

What it costs to run

About 1,187 kWh a year at SEER2 14.3, or roughly $258 at Michigan's average residential rate of 21.73¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Roseville

Of the 28,200 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (33%), 13,000 is sun on the house (46%), 2,120 is four people and their appliances, and 3,700 is moisture the coil has to wring out of Roseville's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.

Other house sizes in Roseville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft15,3001.5 tons2 tons
1,500 sq ft21,7002 tons2.5 tons
2,500 sq ft34,6003 tons5 tons
3,000 sq ft41,0003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 4,900 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,500 BTU/hr.

Month by month in Roseville

MonthAvg highCooling degree daysAC kWh
Jan32.4°F00
Feb35°F00
Mar44.9°F11
Apr57.6°F45
May69.5°F4766
Jun79.2°F174241
Jul83.5°F287399
Aug81.4°F241334
Sep74.3°F91126
Oct61.4°F1014
Nov48.2°F00
Dec37.2°F00

Jul alone uses 34% of the year's cooling energy. The unit runs the equivalent of 603 hours a year at full output.

Roseville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Fraser, MI2 mi87°F2 tons
St. Clair Shores, MI3 mi88°F2.5 tons
Eastpointe, MI3 mi88°F2.5 tons
Warren, MI5 mi88°F2.5 tons
Harper Woods, MI5 mi88°F2.5 tons
Grosse Pointe Woods, MI5 mi88°F2.5 tons

Of 90 Michigan cities here, Roseville has the 14th highest cooling load. The range runs from Marquette at 18,700 BTU/hr to Ypsilanti at 28,800.

Where Roseville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Detroit City Airport, 7.9 miles from the center of Roseville at 623 ft above sea level. That is close enough that the station's summers are Roseville's summers.

17 other cities use the same station and get the same climate inputs. The closest to Roseville: St. Clair Shores (3 mi away, 8.4 mi from the station), Eastpointe (3 mi away, 5.2 mi from the station), Warren (5 mi away, 6 mi from the station), Harper Woods (5 mi away, 4.6 mi from the station), Grosse Pointe Woods (5 mi away, 6 mi from the station). Roseville is farther from the station than 9 of them.

The sun over Roseville in late July

At 42.51°N, the noon sun on 21 July stands 67.9° above the horizon over Roseville and the day runs 14 h 39 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

47,047 people live in Roseville, the 27th largest of the 90 Michigan cities sized on this site. Coordinates used: 42.5076, -82.9366.

Roseville AC sizing questions

What size AC does a 2,000 sq ft house in Roseville, MI need?

About 2.5 tons, for a cooling load of 28,200 BTU/hr on a 88°F design day. That is one ton per 853 square feet in Roseville's climate.

Is 20 BTU per square foot right for Roseville?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Detroit City Airport. For a single room here, plan on 14.1 BTU/hr per square foot.

What does central AC cost to run in Roseville?

About $258 a year: 1,187 kWh at SEER2 14.3 and 21.73¢ per kWh, over 4 cooling months.