What size AC for Grosse Pointe Woods, MI? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Grosse Pointe Woods needs
2.5 tons central AC or heat pump, about 28,200 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 49% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 853 square feet in this climate. For a single room, size by the room: 14.1 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Detroit City Airport (6 mi away). Jul is the hottest month, averaging a high of 83.5°F and a low of 64.9°F, with about 13 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.
What it costs to run
About 1,187 kWh a year at SEER2 14.3, or roughly $258 at Michigan's average residential rate of 21.73¢ per kWh. Cooling runs 4 months of the year here.
What drives the load in Grosse Pointe Woods
Of the 28,200 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (33%), 13,000 is sun on the house (46%), 2,120 is four people and their appliances, and 3,700 is moisture the coil has to wring out of Grosse Pointe Woods's summer air (13%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.
Other house sizes in Grosse Pointe Woods
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 15,300 | 1.5 tons | 2 tons |
| 1,500 sq ft | 21,700 | 2 tons | 2.5 tons |
| 2,500 sq ft | 34,600 | 3 tons | 5 tons |
| 3,000 sq ft | 41,000 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 4,900 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,500 BTU/hr.
Month by month in Grosse Pointe Woods
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 32.4°F | 0 | 0 |
| Feb | 35°F | 0 | 0 |
| Mar | 44.9°F | 1 | 1 |
| Apr | 57.6°F | 4 | 5 |
| May | 69.5°F | 47 | 66 |
| Jun | 79.2°F | 174 | 241 |
| Jul | 83.5°F | 287 | 399 |
| Aug | 81.4°F | 241 | 334 |
| Sep | 74.3°F | 91 | 126 |
| Oct | 61.4°F | 10 | 14 |
| Nov | 48.2°F | 0 | 0 |
| Dec | 37.2°F | 0 | 0 |
Jul alone uses 34% of the year's cooling energy. The unit runs the equivalent of 603 hours a year at full output.
Grosse Pointe Woods against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Harper Woods, MI | 2 mi | 88°F | 2.5 tons |
| Eastpointe, MI | 3 mi | 88°F | 2.5 tons |
| St. Clair Shores, MI | 4 mi | 88°F | 2.5 tons |
| Grosse Pointe Park, MI | 5 mi | 88°F | 2.5 tons |
| Roseville, MI | 5 mi | 88°F | 2.5 tons |
| Fraser, MI | 7 mi | 87°F | 2 tons |
Of 90 Michigan cities here, Grosse Pointe Woods has the 29th highest cooling load. The range runs from Marquette at 18,700 BTU/hr to Ypsilanti at 28,800.
Where Grosse Pointe Woods's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Detroit City Airport, 6 miles from the center of Grosse Pointe Woods at 623 ft above sea level. That is close enough that the station's summers are Grosse Pointe Woods's summers.
17 other cities use the same station and get the same climate inputs. The closest to Grosse Pointe Woods: Harper Woods (2 mi away, 4.6 mi from the station), Eastpointe (3 mi away, 5.2 mi from the station), St. Clair Shores (4 mi away, 8.4 mi from the station), Grosse Pointe Park (5 mi away, 4.9 mi from the station), Roseville (5 mi away, 7.9 mi from the station). Grosse Pointe Woods is farther from the station than 6 of them.
The sun over Grosse Pointe Woods in late July
At 42.44°N, the noon sun on 21 July stands 68.0° above the horizon over Grosse Pointe Woods and the day runs 14 h 39 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
15,897 people live in Grosse Pointe Woods, the 61st largest of the 90 Michigan cities sized on this site. Coordinates used: 42.4393, -82.8990.
Grosse Pointe Woods AC sizing questions
What size AC does a 2,000 sq ft house in Grosse Pointe Woods, MI need?
About 2.5 tons, for a cooling load of 28,200 BTU/hr on a 88°F design day. That is one ton per 853 square feet in Grosse Pointe Woods's climate.
Is 20 BTU per square foot right for Grosse Pointe Woods?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Detroit City Airport. For a single room here, plan on 14.1 BTU/hr per square foot.
What does central AC cost to run in Grosse Pointe Woods?
About $258 a year: 1,187 kWh at SEER2 14.3 and 21.73¢ per kWh, over 4 cooling months.