What size AC for Palmdale, CA? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Palmdale needs

4 tons central AC or heat pump, about 42,200 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.5 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 568 square feet in this climate. For a single room, size by the room: 21.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Palmdale Airport (2.9 mi away). Aug is the hottest month, averaging a high of 97.7°F and a low of 66°F, with about 113 days a year at 90°F or more. That gives a design temperature of 105°F against 75°F inside.

What it costs to run

About 2,702 kWh a year at SEER2 14.3, or roughly $880 at California's average residential rate of 32.58¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Palmdale

Of the 42,200 BTU/hr, 21,600 comes through walls, roof and windows on a 105°F afternoon (51%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 5,500 is moisture the coil has to wring out of Palmdale's summer air (13%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,720 BTU/hr before the moisture allowance.

Other house sizes in Palmdale

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,3002 tons2 tons
1,500 sq ft32,3003 tons2.5 tons
2,500 sq ft52,2005 tons5 tons
3,000 sq ft62,1005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,700 BTU/hr.

Month by month in Palmdale

MonthAvg highCooling degree daysAC kWh
Jan58.9°F00
Feb61.8°F00
Mar67.5°F23
Apr73.4°F2737
May82°F141196
Jun91°F322447
Jul97.6°F542754
Aug97.7°F522726
Sep91.6°F314436
Oct79.7°F72100
Nov67.3°F22
Dec57.7°F00

Jul alone uses 28% of the year's cooling energy. The unit runs the equivalent of 915 hours a year at full output.

Palmdale against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Lancaster, CA8 mi105°F4 tons
Santa Clarita, CA26 mi100°F3.5 tons
La Cañada Flintridge, CA27 mi95°F3 tons
San Fernando, CA28 mi100°F3.5 tons
Sierra Madre, CA29 mi89°F2.5 tons
Glendale, CA29 mi95°F3 tons

Of 376 California cities here, Palmdale has the 39th highest cooling load. The range runs from Corte Madera at 15,700 BTU/hr to Palm Desert at 59,000.

Where Palmdale's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Palmdale Airport, 2.9 miles from the center of Palmdale at 2,509 ft above sea level. That is close enough that the station's summers are Palmdale's summers.

No other city in this set uses Palmdale Airport, so this sizing is Palmdale's alone.

The sun over Palmdale in late July

At 34.59°N, the noon sun on 21 July stands 75.8° above the horizon over Palmdale and the day runs 13 h 59 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

162,536 people live in Palmdale, the 33rd largest of the 376 California cities sized on this site. Coordinates used: 34.5910, -118.1054.

Palmdale AC sizing questions

What size AC does a 2,000 sq ft house in Palmdale, CA need?

About 4 tons, for a cooling load of 42,200 BTU/hr on a 105°F design day. That is one ton per 568 square feet in Palmdale's climate.

Is 20 BTU per square foot right for Palmdale?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Palmdale Airport. For a single room here, plan on 21.1 BTU/hr per square foot.

What does central AC cost to run in Palmdale?

About $880 a year: 2,702 kWh at SEER2 14.3 and 32.58¢ per kWh, over 6 cooling months.