ACSizeCheck

What size AC for Painesville, OH? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Painesville needs

2.5 tons central AC or heat pump, about 26,500 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 59% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 906 square feet in this climate. For a single room, size by the room: 13.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Painesville 4 Nw (2.9 mi away). Jul is the hottest month, averaging a high of 82.3°F and a low of 66.9°F, with about 5 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.

What it costs to run

About 1,327 kWh a year at SEER2 14.3, or roughly $250 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Painesville

Of the 26,500 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (30%), 13,000 is sun on the house (49%), 2,120 is four people and their appliances, and 3,500 is moisture the coil has to wring out of Painesville's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.

Other house sizes in Painesville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,5001.5 tons2 tons
1,500 sq ft20,5002 tons2.5 tons
2,500 sq ft32,5003 tons5 tons
3,000 sq ft38,5003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.

Month by month in Painesville

MonthAvg highCooling degree daysAC kWh
Jan36.8°F00
Feb38.7°F00
Mar46.1°F01
Apr58.1°F710
May69.1°F5171
Jun78.1°F175243
Jul82.3°F298414
Aug81.6°F270375
Sep76.2°F129180
Oct64.9°F2433
Nov52.6°F11
Dec42°F00

Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 716 hours a year at full output.

Painesville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Mentor, OH5 mi86°F2.5 tons
Willoughby, OH10 mi85°F2 tons
Eastlake, OH10 mi85°F2 tons
Willowick, OH12 mi85°F2 tons
Wickliffe, OH13 mi85°F2 tons
Euclid, OH16 mi85°F2 tons

Of 176 Ohio cities here, Painesville has the 120th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Painesville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Painesville 4 Nw, 2.9 miles from the center of Painesville at 600 ft above sea level. That is close enough that the station's summers are Painesville's summers.

1 other city uses the same station and get the same climate inputs. The closest to Painesville: Mentor (5 mi away, 4.8 mi from the station). Painesville sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Painesville in late July

At 41.72°N, the noon sun on 21 July stands 68.7° above the horizon over Painesville and the day runs 14 h 35 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

20,660 people live in Painesville, the 82nd largest of the 176 Ohio cities sized on this site. Coordinates used: 41.7216, -81.2584.

Painesville AC sizing questions

What size AC does a 2,000 sq ft house in Painesville, OH need?

About 2.5 tons, for a cooling load of 26,500 BTU/hr on a 86°F design day. That is one ton per 906 square feet in Painesville's climate.

Is 20 BTU per square foot right for Painesville?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Painesville 4 Nw. For a single room here, plan on 13.2 BTU/hr per square foot.

What does central AC cost to run in Painesville?

About $250 a year: 1,327 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.