ACSizeCheck

What size AC for Eastlake, OH? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Eastlake needs

2 tons central AC or heat pump, about 25,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 64% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 935 square feet in this climate. For a single room, size by the room: 12.8 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cleveland Burke Lakefront Airport (15.4 mi away). Jul is the hottest month, averaging a high of 80.7°F and a low of 67.9°F, with about 9 days a year at 90°F or more. That gives a design temperature of 85°F against 75°F inside.

What it costs to run

About 1,285 kWh a year at SEER2 14.3, or roughly $242 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Eastlake

Of the 25,700 BTU/hr, 7,200 comes through walls, roof and windows on a 85°F afternoon (28%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 3,300 is moisture the coil has to wring out of Eastlake's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 22,320 BTU/hr before the moisture allowance.

Other house sizes in Eastlake

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,1001.5 tons2 tons
1,500 sq ft19,9001.5 tons2.5 tons
2,500 sq ft31,5003 tons5 tons
3,000 sq ft37,3003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,700 BTU/hr.

Month by month in Eastlake

MonthAvg highCooling degree daysAC kWh
Jan35.3°F00
Feb37.3°F00
Mar44.9°F12
Apr57.1°F810
May67.9°F5678
Jun76.7°F178248
Jul80.7°F289402
Aug79.7°F261363
Sep73.5°F112156
Oct62.5°F1826
Nov50.5°F11
Dec40.1°F00

Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 716 hours a year at full output.

Eastlake against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Willoughby, OH1 mi85°F2 tons
Willowick, OH3 mi85°F2 tons
Wickliffe, OH4 mi85°F2 tons
Mentor, OH5 mi86°F2.5 tons
Euclid, OH6 mi85°F2 tons
Richmond Heights, OH8 mi85°F2 tons

Of 176 Ohio cities here, Eastlake has the 155th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Eastlake's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cleveland Burke Lakefront Airport, 15.4 miles from the center of Eastlake at 582 ft above sea level. That is close enough that the station's summers are Eastlake's summers.

22 other cities use the same station and get the same climate inputs. The closest to Eastlake: Willoughby (1 mi away, 15.6 mi from the station), Willowick (3 mi away, 12.8 mi from the station), Wickliffe (4 mi away, 11.8 mi from the station), Euclid (6 mi away, 9 mi from the station), Richmond Heights (8 mi away, 8.7 mi from the station). Eastlake is farther from the station than 19 of them.

The sun over Eastlake in late July

At 41.66°N, the noon sun on 21 July stands 68.7° above the horizon over Eastlake and the day runs 14 h 35 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

17,423 people live in Eastlake, the 108th largest of the 176 Ohio cities sized on this site. Coordinates used: 41.6566, -81.4291.

Eastlake AC sizing questions

What size AC does a 2,000 sq ft house in Eastlake, OH need?

About 2 tons, for a cooling load of 25,700 BTU/hr on a 85°F design day. That is one ton per 935 square feet in Eastlake's climate.

Is 20 BTU per square foot right for Eastlake?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Cleveland Burke Lakefront Airport. For a single room here, plan on 12.8 BTU/hr per square foot.

What does central AC cost to run in Eastlake?

About $242 a year: 1,285 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.