What size AC for Newberry, SC? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Newberry needs

3.5 tons central AC or heat pump, about 38,700 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.2 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 621 square feet in this climate. For a single room, size by the room: 19.3 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Newberry (1.4 mi away). Jul is the hottest month, averaging a high of 91.4°F and a low of 69.9°F, with about 70 days a year at 90°F or more. That gives a design temperature of 98°F against 75°F inside.

What it costs to run

About 2,727 kWh a year at SEER2 14.3, or roughly $434 at South Carolina's average residential rate of 15.9¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Newberry

Of the 38,700 BTU/hr, 16,560 comes through walls, roof and windows on a 98°F afternoon (43%), 13,000 is sun on the house (34%), 2,120 is four people and their appliances, and 7,000 is moisture the coil has to wring out of Newberry's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 31,680 BTU/hr before the moisture allowance.

Other house sizes in Newberry

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft20,6002 tons2 tons
1,500 sq ft29,6002.5 tons2.5 tons
2,500 sq ft47,7004 tons5 tons
3,000 sq ft56,7005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,900 BTU/hr; a 350 sq ft living room needs about 6,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,600 BTU/hr.

Month by month in Newberry

MonthAvg highCooling degree daysAC kWh
Jan54.1°F11
Feb58°F11
Mar65.2°F812
Apr74.1°F4972
May81.5°F182268
Jun88.2°F371546
Jul91.4°F485715
Aug89.2°F429633
Sep84.2°F259382
Oct74.7°F5987
Nov64.1°F58
Dec56.7°F12

Jul alone uses 26% of the year's cooling energy. The unit runs the equivalent of 1,009 hours a year at full output.

Newberry against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Irmo, SC26 mi99°F4 tons
Lexington, SC29 mi99°F4 tons
Greenwood, SC32 mi96°F3.5 tons
West Columbia, SC35 mi99°F4 tons
Cayce, SC39 mi100°F4 tons
Forest Acres, SC40 mi100°F4 tons

Of 42 South Carolina cities here, Newberry has the 22nd highest cooling load. The range runs from Gaffney at 32,300 BTU/hr to Columbia at 43,100.

Where Newberry's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Newberry, 1.4 miles from the center of Newberry at 513 ft above sea level. That is close enough that the station's summers are Newberry's summers.

No other city in this set uses Newberry, so this sizing is Newberry's alone.

The sun over Newberry in late July

At 34.28°N, the noon sun on 21 July stands 76.1° above the horizon over Newberry and the day runs 13 h 57 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

10,874 people live in Newberry, the 41st largest of the 42 South Carolina cities sized on this site. Coordinates used: 34.2799, -81.6003.

Newberry AC sizing questions

What size AC does a 2,000 sq ft house in Newberry, SC need?

About 3.5 tons, for a cooling load of 38,700 BTU/hr on a 98°F design day. That is one ton per 621 square feet in Newberry's climate.

Is 20 BTU per square foot right for Newberry?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Newberry. For a single room here, plan on 19.3 BTU/hr per square foot.

What does central AC cost to run in Newberry?

About $434 a year: 2,727 kWh at SEER2 14.3 and 15.9¢ per kWh, over 6 cooling months.